1
2
5
6
7
8
9
10
11
12
4
3
Fig. 5:
Design, horizontal direction of flow
1 Filler screw
7
Connecting cable, fan/temperature sensor
2 Measurement connection vacuum side
8
Sight glass motor side
3 Motor power supply plug
9
Fan cover
4 Filler screw
10
Vacuum flange with flange cover (foil)
5 Measurement connection fore-vacuum side
11
Sight glass, opposite side
6 Fore-vacuum flange with flange cover (foil)
12
Connecting cable, fan/temperature sensor
Temp. 1
Temp. water
(optional)
Temp. exhaust
gas (optional)
Temp. 2
Fan 1
n. c.
cooling water
mon. (optional)
Fan 2
8
6
2
7
3
4
5
1
Fig. 6:
Design, switch box
1 Switch box
5
Sensor connections
2 Operator panel
6
Motor connection
3 Fan grille, inlet
7
Mains connection
4 Underside of control cabinet
8
Fan grille, outlet
3.1.1 Drive
The drive of the vacuum pump is carried out coupling-free in "Cantilever design". Due to the motor de-
sign, the vacuum pump is compact, hermetically sealed and also has a high efficiency. The frequency
converter takes over the control of the vacuum pump and permits the adjustment of the speed to the
actual process requirements (in the valid speed range).