Type des-
ignation
HiCube 400
Pro
HiCube 400
Pro
HiCube 400
Pro
HiCube 400
Pro
HiCube 400
Pro
Power con-
sumption
max.
910 W
1160 W
940 W
1420 W
1900 W
Sound
pressure
level
≤50 dB(A)
≤50 dB(A)
≤50 dB(A)
≤50 dB(A)
≤50 dB(A)
Cooling
method,
standard
Air
Air
Air
Air
Air
Relative
humidity of
air
5 – 85 %, non-
condensing
5 – 85 %, non-
condensing
5 – 85 %, non-
condensing
5 – 85 %, non-
condensing
5 – 85 %, non-
condensing
Shipping
and storage
tempera-
ture
-10 – 55 °C
-10 – 55 °C
-10 – 50 °C
-10 – 50 °C
-10 – 50 °C
Weight
73 kg
96 kg
76.9 kg
81.9 kg
80.9 kg
Tbl. 35:
Technical data HiCube 400 Pro, DN 100 ISO-K
Type designa-
tion
HiCube 400 Pro
HiCube 400 Pro
HiCube 400 Pro
HiCube 400 Pro
Connection
flange (in)
DN 100 ISO-K
DN 100 ISO-K
DN 100 ISO-K
DN 100 ISO-K
Connection
flange (out)
G 1/2
G 1/2
G 1/2
G 1/2
Turbopump
HiPace 400
HiPace 400
HiPace 400
HiPace 400
Backing pump
Duo 11 M
Duo 20 M
Pascal 2010
Pascal 2021
Final pressure
without gas bal-
last
< 1 · 10
-7
hPa
< 1 · 10
-7
hPa
< 1 · 10
-7
hPa
< 1 · 10
-7
hPa
Pumping speed
for N
2
355 l/s
355 l/s
355 l/s
355 l/s
Pumping speed
backing pump at
50 Hz
9 m³/h
20 m³/h
9 m³/h
18 m³/h
Input voltage(s)
200 – 240 V AC,
50/60 Hz
200 – 230 V AC,
50/60 Hz
200 – 230 V AC,
50/60 Hz
200 – 230 V AC,
50/60 Hz
Input voltage: tol-
erance
±10 %
±10 %
±10 %
±10 %
Motor for region
Asia, Europe
Asia, Europe
Asia, Europe
Asia, Europe
Power consump-
tion max.
750 W
1350 W
1000 W
1000 W
Sound pressure
level
≤50 dB(A)
≤50 dB(A)
≤50 dB(A)
≤50 dB(A)
Cooling method,
standard
Air
Air
Air
Air
Relative humidity
of air
5 – 85 %, non-
condensing
5 – 85 %, non-
condensing
5 – 85 %, non-
condensing
5 – 85 %, non-
condensing
Shipping and
storage tempera-
ture
-20 – 55 °C
-20 – 55 °C
-20 – 55 °C
-20 – 55 °C
Weight
71 kg
96 kg
78 kg
80 kg
Tbl. 36:
Technical data HiCube 400 Pro, DN 100 ISO-K
Technical data and dimensions
69/80