38
Advanced settings
7.3
Water circuit
The water circuit dissipates heat from the functional block to protect the mechanical and
electrical components (motors and frequency converters).
It is also used for thermal regulation of the high pressure (HP) and low pressure (LP)
stages of the functional block (FB)
.
Fig. 10: A 124H/A 204H/A 204X water circuit
Fig. 11: Water circuit for other models
7
LP water valve
Temperature of the HP/LP stages regulation
8
HP water valve
9
Water Flowmeter
Water flow measurement
10
Manual valve
Roots cooling authorization
T
C
Temperature sensor
Motor temperature measurement
T
R
Temperature sensor
Roots motor temperature measurement (A 604/A 804)
T
HP
HP temperature sensor
FB temperature measurement
T
BP
LP temperature sensor
BF
Functional block
FC
BF
T
BP
T
HP
T
C
7
8
9
FC
FC
BF
Roots
V1
T
BP
T
HP
T
C
T
C
T
R
7
8
9