Parameter Settings
19
The standard values listed in the table are basic settings, which can be altered if
necessary.
For more displays and information see the motor instruction manual.
6
Parameter Settings
Group
Parameter
Description
Access level
Adjustment
range
Standard value
2
251 Presser foot clearance when raised
by pedal (pedal position –2)
B, C
0 - 255
160
252 Presser foot clearance when raised
by knee switch
B, C
0 - 255
150
256 Min. presser foot pressure during sewing
B, C
0 - 32
10
258 Machine feed type
1 = needle feed, 0 = bottom feed
B, C
0 - 1
0
287 Presser foot clearance when raised
by pedal (pedal position –1)
B, C
0 - 255
150
288 Presser foot holding pressure while the
M/C is stoped
B, C
0 - 255
80
6
607 Maximum speed
B, C
300 - 5500
4000
660 Bobbin thread monitoring
0 = off
1 = by sensor (-926/06)
2 = by stitch counting
B, C
0 - 2
1180
= 1
938 U
= 0
7
700 Needle position 0
(needle reference position
B, C
0 - 255
*
702 Needle position 1 (needle lowered)
B, C
0 - 255
90
703 Needle position 2 (take-up lever raised)
B, C
0 - 255
236
760 Multiplier for the fixed value (200) for
stitch count
A,B, C
0 - 250
5
799 Selected machine class
C
1 - 2
1
8
800 Rotating direction of the motor
C
0 - 1
0
9
985 Switch on angle for thread trapper
B,C
0 - 255
67
986 Switch off angle for thread trapper
B,C
0 - 255
206
989 Thread trapper at beginning of seam
1 = yes, 0 = no
B,C
0 - 2
0
*
Adjustment see Chapter
3.01
Basic position of the machine drive unit.
Summary of Contents for 1180 U Series
Page 24: ...24 Circuit diagrams Version 05 11 03 91 191 478 95 Part1...
Page 25: ...25 91 191 478 95 Part 2 Version 05 11 03 Circuit diagrams...
Page 26: ...26 Circuit diagrams Version 05 11 03 91 191 478 95 Part3...
Page 28: ...28 Circuit diagrams Version 12 01 07 91 191 517 95 Part1...
Page 29: ...29 91 191 517 95 Part 2 Version 12 01 07 Circuit diagrams...
Page 30: ...30 Circuit diagrams Version 12 01 07 91 191 517 95 Part 3...
Page 31: ...Notes...