22 1-800-732-2677
Test the Warning Zone
1. With the Receiver Collar on the Receiver Handle, turn ON the Receiver Collar and verify the battery is
charged.
2. Verify that the boundary programmed correctly by approaching the Boundary Flags from inside the Pet
Area. Don’t move the Receiver Collar back and forth like a pendulum. Do not walk or move the Receiver
Collar backwards.
Always hold the Receiver Handle so that the PetSafe logo on the Receiver Collar is
facing toward your direction of motion.
3. The Receiver Collar should generate a warning tone as you approach the flag. This distance will vary
slightly but should be close to the Boundary Flag location.
4. Next, continue beyond the boundary flag. One to five feet beyond the Boundary Flags location is where
the Receiver activates the Run-Through stimulation level. The Receiver Collar generates three distinct
Warning Tones to assist you in determining the Receiver Activation Status.
5. As you’re testing the boundary, you may notice the Receiver Collar no longer responds when you cross the
boundary. This is due to the Receiver Collar entering the Over Protection Correction mode as described
in Step 3. After about 15 seconds of anti-linger or normal Static Correction, the Receiver Collar will enter
a time-out condition, the green light will turn ON for 10 seconds, and you must allow for a full 10 seconds
recovery time (and be back inside the Pet Area) before the Receiver Collar will again respond to the
boundary.
6. If the Receiver Collar fails to detect the boundary, then time-out is the likely cause. Wait 10 seconds with
Receiver Collar located inside Pet Area and try again.
7. Walk along the Pet Area, especially around AC power entrances, cable TV and phone line entrances into
the home, and near air conditioning units. Make sure the collar does not tone in the area where your dog
should be free to play. If there are problems, you will need to adjust your layout to exclude these areas or
possibly move your Transmitter to a different location. Reminder: If you move the Transmitter you will need
to reprogram your Boundary.
Test Light Instructions
If you have difficulty hearing the tone, use the test light tool. Remove from the Receiver Handle first.
1. Set the Correction Level to 2 or above.
2. Hold the Test Light Contacts to the Receiver
Collar Contact Points (
9A
).
3. When moving, the PetSafe
®
logo must be
pointed in the direction of forward motion.
PetSafe
®
logo must be forward and facing
the outward direction, facing away from the
Transmitter.
4. Walk toward the Boundary Zone holding the
Receiver Collar at your pet’s neck level (
9B
)
until the Test Light flashes (
9C
). Save Test
Light for future testing.
9B
Bou
ndary
Zone
Pet
Area
9C
9A