PREVENTIVE MAINTENANCE SCHEDULE
PREVENTIVE MAINTENANCE (PM) INTERVALS
Recommended PM
Interval
SYSTEM
COMPONENT
MAINTENANCE TASK
I
A
B
C
Check the "cold" fill level at the differential carrier plug for a pinion
angle of less than 7 degrees, or at the axle bowl plug for a pinion
angle of greater than 7 degrees. Tighten the plug to 35-50 Lb.
ft. (47-68 N.m.)
X
Visually inspect for damage or leaks.
X
Axle Housing
Drain and replace the lubricant.
See information on page
Lubricant filter
Change the filter.
X
Breather
Check the operation. If the cap doesn’t rotate freely, replace.
X
Input shaft & pinion shaft
Check and adjust the endplay.
X
Axle shaft
Tighten the rear axle flange nuts to the specified torque value.
X
Drive Axle
(Meritor)
Interaxle differential
Check the operation.
X
(03/17)
Y53-6060-1C1
5-19