background image

6

VB230/400-6/25/30L (LP)

6.

Block diagram

Explanation:   

The designations for the housing variant are indicated without brackets,

 

       whereas those applicable for the circuit-board version are put into brackets.

Brems-

relais

Controller

(L1)

1L1

(L2)

3L2

2T1

(T1)

4T2

(T2)

6T3

(T3)

X5

X6

(X10)

(X11)

Current detection

(X1)

X3

(X2)

X4

Fault

only available with circuit-board version (LP)

24V
5V

X7

Interlocking

Summary of Contents for VB 230-25 L

Page 1: ...e l e c t r o n i c Quality is our Drive Braking Devices VB 230 400 6 25 30L LP Assembly and Commissioning Instructions...

Page 2: ...rcuit board version 8 8 Control inputs and outputs 9 8 1 Control input 9 8 2 Control outputs 10 9 Potentiometers 11 10 Technical data 12 10 1 Environmental conditions 13 11 Commissioning 13 11 1 Mount...

Page 3: ...n you see this sign always make sure that the device is de energized and secured against unintentional energizing These commissioning instructions were prepared with great care Nevertheless PETER elec...

Page 4: ...tion and the trade associations apply in Germany The user must ensure that the drive turns into a safe operating state following a device failure in the event of maloperation or if the control unit ha...

Page 5: ...version additi onally via a fault signalling contact Special features controlled by microcontroller wear resistant and maintenance free for three phase asynchronous motors for mono phase motors retrof...

Page 6: ...EU directives 2014 30 EU 2014 35 EU 2011 65 EU This EC Declaration of Conformity is no longer valid if the product is modified or changed without our agreement This declaration is issued under the so...

Page 7: ...ant are indicated without brackets whereas those applicable for the circuit board version are put into brackets Brems relais Controller L1 1L1 L2 3L2 2T1 T1 4T2 T2 6T3 T3 X5 X6 X10 X11 Current detecti...

Page 8: ...eform switches the braking current off approx 1 5s after a motor standstill has been detected To be able to adapt the device to a variety of motors it is possible to adjust the stand still threshold v...

Page 9: ...t was not reached Braking frequency too high 3x in succession no motor stillstand detected LED I V16 Illuminated Operational status Braking current is flowing No voltage applied to VB L Contakt X10 X1...

Page 10: ...with connected starting contact this means that the motor can be restarted during the braking delay time remanence time Caution Danger to life through electric shock The terminals X3 X1 X4 X2 carry ma...

Page 11: ...in order to interconnect the motor winding For more detailed information please see connection diagram on page 20 X10 X11 Fault signal potential free relay contact In case of a fault this concact open...

Page 12: ...king time The LED indicates no standstill during the max braking time I P2 Adjusting the braking current The braking current can be adjusted in the range from approx 10 100 of the rated device current...

Page 13: ...rated motor currents on IE3 Motors 0 3 2A 2 9A 2 12A 0 3 2A 2 9A 2 12A Rated device current 6A 25A 30A 6A 25A 30A c d f at max braking current 60 8 5 60 8 5 I t value of power semiconductors 310 A s...

Page 14: ...he VersiBrake L LP 1 The device series VersiBrake L LP is to be used under overvoltage conditions of the category III 2 Make sure that pollution degree 2 or better in accordance with IEC664 is complie...

Page 15: ...2 Since the potentiometer reacts roughly linear it is possible to infer the braking current from the potentiometer setting Left stop counter clockwise direction roughly equals 10 of the rated device c...

Page 16: ...r has come to a rest it is possible to make an adjustment with this potentiometer Turn to the left Detection becomes more sensitive Brake current may switch off too soon Turn to the right Detection be...

Page 17: ...hreshold is not adapted Adapt standstill threshold with n0 Flashing 2x Adjusted braking current was not reached Interruption in the braking circuit Possibly the motor is started with star delta connec...

Page 18: ...is allowed to be inoperative 2 Fusing according to allocation type 2 DIN EN 60947 4 2 After a short circuit the braking device must be suitable for further use However there is the danger that the co...

Page 19: ...fuse should not be smaller than the braking current to be expected rated device current Note 1 On the basis of the recommended I t value braking current and possibly the c d f the fuse supplier is ab...

Page 20: ...ting conditions however the device needs a recovery time of 15 minutes Braking current Braking time Braking frequency VB 6 L 6A 5s 10s 1 braking operation per 8s 1 braking operation per 16s VB 6 L 3A...

Page 21: ...Braking time Non braking time Cyclicdurationfactor r c d f tB Cycletime 100 Load curve for VB 400 6 L LP 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 Cyclic duration factor in Per...

Page 22: ...50 60 70 80 90 100 Cyclic duration factor in Permissible max braking current in of the rated device current 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 Cyclic duration factor in...

Page 23: ...22 VB230 400 6 25 30L LP 13 Dimensions Enclosed version with housing Printed circuit board version All dimensions indicated in mm 45 73 120 105 100 58...

Page 24: ...X7 The limit values for emitted interference according to the applicable device standards do not rule out the possibility that receivers and susceptible electronic devices within a radius of 10m are...

Page 25: ...24 VB230 400 6 25 30L LP...

Page 26: ......