Connecting the Regulator to the CO
2
Cylinder
■ Remove blue plug from regulator fitting.
(Note: Do not remove the carbonic washer).
■ Screw regulator onto gas cylinder valve.
Tighten with wrench until vertically straight.
Be sure that shut-off valve
(lever)
on
regulator is in the OFF
(horizontal)
position.
■ Place a screw clamp over end of red air line
and push onto regulator tailpiece. Tighten
clamp with a screwdriver.
Adjusting the CO
2
Gas Flow
■ Turn regulator adjusting screw
counterclockwise until it turns freely.
■ Turn hand valve counterclockwise on CO2
cylinder to the fully open position.
■ Turn regulator adjusting screw clockwise until
desired pressure is reached (approximately
12-15 lbs.). Tighten stop nut on adjusting screw.
■ Open shut-off valve on bottom of regulator.
CO
2
Leak Test
Dilute a small amount of liquid dishwashing soap
and rub the soapy mixture around each
connection. If bubbles appear, tighten connection.
Replacing CO
2
Gas Cylinder
■ Turn CO2 hand valve clockwise until seated
and close shut-off valve on regulator.
■ Unscrew regulator from cylinder fitting.
■ Replace carbonic washer (Part No.
if needed and reattach regulator to filled
cylinder.
■ Turn CO2 hand valve counterclockwise until
fully open. Turn regulator shut-off valve to
open position.
■ Adjust CO2 gas flow as required, turning
clockwise for higher pressure.
Proper CO
2
Handling
ALWAYS...
■ Connect a regulator (reducing valve) to CO2
cylinder.
■ Secure cylinder in upright position whether in
storage or in use.
■ Keep cylinder away from heat. Rupture disc
vents at 122° F. maximum.
■ Ventilate room after high pressure gas leakage.
■ Check the last DOT test date on cylinder neck
before filling. If more than five years old, the
cylinder must be retested to DOT specifications.
■ Be sure CO2 cylinder outlet fitting is free of
dust or dirt before attaching regulator.
■ Store CO2 cylinder and regulator assembly
upright.
■ Allow only properly trained and experienced
personnel to handle high pressure gas.