Perlick BC24 Series Installation And Operation Instructions Manual Download Page 1

INSTALLATION AND OPERATION INSTRUCTIONS

FLAT TOP BOTTLE COOLER

Table of Contents

Cabinet Specifications ..........................................2
Installing

Uncrating and Inspection ................................3
Plumbing .........................................................3
Electrical..........................................................3
Adjusting Partitions .........................................3
Installing Casters and Legs.............................3
Placing the Cabinet.........................................3
Sealing to the Floor.........................................3

Temperature Control .............................................4
Cleaning the Cabinet ............................................4
Wiring Diagram .....................................................5
Replacement Parts ............................................6/7

8300 West Good Hope Road  •  Milwaukee, WI 53223  •  Phone 414-353-7060  •  Fax 414-353-7069

Toll Free 800-558-5592  •  E-Mail: [email protected]  •  www.Perlick.com

IMPORTANT INFORMATION

This manual has been prepared to assist you in the
installation of your Bottle Cooler and to acquaint you
with its operation and maintenance.

We dedicate considerable time to ensure that our
products provide the highest level of customer 
satisfaction. If service is required, call Perlick at
1-800-777-7267 or your dealer who can provide you
with a list of qualified service agents. For your own
protection, never return merchandise for credit with-
out our approval.

We thank you for selecting a Perlick product and
assure you of our continuing interest in your
satisfaction.

IMPORTANT WARRANTY INFORMATION

A Warranty card is enclosed that must be completed
and mailed to the Perlick Corporation to register the
warranty. If the card is not returned to Perlick, the
warranty period will begin from the date the
equipment is shipped from the factory.

MODEL NOS.

BC24 Series
BC36 Series
BC48 Series
BC60 Series
BC72 Series
BC96 Series

Form No. Z2219

Rev. 4.15.06

Summary of Contents for BC24 Series

Page 1: ... operation and maintenance We dedicate considerable time to ensure that our products provide the highest level of customer satisfaction If service is required call Perlick at 1 800 777 7267 or your dealer who can provide you with a list of qualified service agents For your own protection never return merchandise for credit with out our approval We thank you for selecting a Perlick product and assu...

Page 2: ...s are 20 gauge black vinyl coated steel Back is galvanized steel Bottom is galvanized steel Stainless Exterior and Stainless Interior Models Front and ends are stainless steel Back is galvanized steel Bottom is galvanized steel All Stainless Models Front ends back and bottom are stainless steel All Models Top is stainless steel Aluminum front and back grilles and stainless steel cap receivers DOOR...

Page 3: ... cans from their cases before placing in cooler to ensure proper air flow On 2 and 3 models keep air intake open for proper circulation Installing Casters or Legs optional Attach casters or legs to the cabinet bottom in holes provided Use the supplied 1 4 20 hex head self tapping machine screws If unit is tipped on its back for an extended period of time wait 24 hours after unit is uprighted to pl...

Page 4: ...uld be periodically removed from the cabinet and inspected for a buildup of foreign materials such as syrups beer etc Buildups on the underside of the doors along with the cabinet breaker strips on which they ride will cause them to bind and therefore not function as designed If dirty these surfaces should be cleaned with a mild detergent and water and then coated with a silicone lubricating mater...

Page 5: ...nge specifications without prior notice Wiring Diagram Flat Top Bottle Coolers GREEN PLUG IN CORD BLACK WHITE WHITE EVAP FAN EVAP FAN 2ND FAN ON 4 THRU 8 MODELS TEMPERATURE CONTROL RED BLACK TO CONDENSING UNIT INSIDE OF CONDENSING UNIT HOUSING INSIDE OF CABINET Form No Z2219 Rev 4 15 06 ...

Page 6: ...nge specifications without prior notice Replacement Parts Flat Top Bottle Coolers 19 17 21 13 12 22 6 14 5 5A 9 7 4 23 8 15 3 10 11 1 2 20 18 Form No Z2219 Rev 4 15 06 Service should be done by a qualified refrigeration technician Disconnect all power before servicing the cabinet CAUTION ...

Page 7: ...e 64167A 1 64643 1 64643 1 64643 1 64643 1 64643 1 12 Door assembly 66397 24L 66397 36L 2 66397 24L 66397 24L 2 66397 36L 2 66397 36L Door assembly multiple doors N A N A N A 66397 36L N A 66397 24L 13 Door Lock 63564 63564 63564 63564 63564 63564 14 Top wiper gasket 63671 24 63671 36 63671 48 63671 60 63671 72 63671 96 15 Bottom floor rack wide 64814 1 64814 1 64814 1 64814 1 64814 1 64814 1 16 B...

Page 8: ...oad Milwaukee WI 53223 Phone 414 353 7060 Fax 414 353 7069 Toll Free 800 558 5592 E Mail Perlick Perlick com www Perlick com Perlick is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice ...

Reviews: