Perlick ARCTICPOUR GB1 Installation And Operation Instructions Manual Download Page 1

MODELS

RD060, RD120, 

RD060-O, RD120-O

GB1, GB2, GB3, GB4

INSTALLATION AND OPERATION INSTRUCTIONS

ARCTICPOUR ADVANCED REFRIGERATION TECHNOLOGY

IMPORTANT INFORMATION

To register your product, visit our web site at 

www.

perlick.com

. Click on 

Commercial

, then 

Service

You will see the link to 

Warranty Registration Form

You must complete and submit this form or the 

installation date will revert back to the ship date.

Permanently mount the enclosed Warning/Safety 

Instruction label in a visible location near the CO2 

regulator.

This manual has been prepared to assist you in the 

installation of your Century Remote Beer System and 

to acquaint you with its operation and maintenance. 

We dedicate considerable time to ensure that our 

products provide the highest level of customer 

satisfaction. If service is required, your dealer can 

provide you with a list of qualified service agents. For 

your own protection, never return merchandise for 

credit without our approval. 

We thank you for selecting a Perlick product and assure 

you of our continuing interest in your satisfaction .

8300 West Good Hope Road   •   Milwaukee, WI  53223   •   Phone  414.353.7060   •   Fax  414.353.7069

Toll Free  800.558.5592   •   E-Mail  [email protected]   •   www.perlick.com

Table of Contents

Dimensional Drawings ............................................... 2

Product Description ................................................... 5

Installation ................................................................. 5

    Important Safety Warnings .................................... 5

    Installing the System ............................................. 5

         All Models ......................................................... 6

    Connecting to a Trunk Housing ............................. 6

    Connecting Trunk Housing to Dispensing Head .... 6

System Pak Start-Up ................................................. 6

Digital Temperature Controller ................................... 7

Preventative Maintenance ......................................... 9

Replacement Parts .................................................... 9

Wiring Diagrams ...................................................... 11

Form No. Z2339

Rev. 04.17.2018

Refrigeration Deck

Glycol Bath

Summary of Contents for ARCTICPOUR GB1

Page 1: ...sure that our products provide the highest level of customer satisfaction If service is required your dealer can provide you with a list of qualified service agents For your own protection never retur...

Page 2: ...L NOS GB1 GB2 GB3 GB4 GB1 C GB2 C DIMENSIONS EXTERIOR mm Length A 24 3 4 629 24 3 4 629 24 3 4 629 24 3 4 629 24 3 4 629 24 3 4 629 Width B 19 483 23 11 16 602 23 11 16 602 23 11 16 602 19 483 23 11 1...

Page 3: ...Perlick Corporation MODEL GB CENTURY II GLYCOL DECK DATE 20 5 16 20 3 4 13 3 16 15 11 16 MOUNTING HOLES 24 3 4 22 15 16 CONNECTIONS 7 8 KNOCKOUT PUMP INLET 1 2 BARB CONNECTIONS 3 8 BARB PRODUCT POWER...

Page 4: ...OPRIETARY INFORMATION WHICH IS THE PROPERTY OF THE PERLICK CORPORATION IT MAY NOT BE REPRODUCED OR TRANSMITTED IN ANY FORM ELECTRONIC OR MECHANICAL INCLUDING PHOTOCOPYING RECORDING OR USED IN ANYINFOR...

Page 5: ...INS PROPRIETARY INFORMATION WHICH IS THE PROPERTY OF THE PERLICK CORPORATION IT MAY NOT BE REPRODUCED OR TRANSMITTED IN ANY FORM ELECTRONIC OR MECHANICAL INCLUDING PHOTOCOPYING RECORDING OR USED IN AN...

Page 6: ...SAFETY WARNINGS Follow all National and Regional codes Read Operation Installation Manual carefully before attempting to install operate or maintain the product Protect yourself and others by observin...

Page 7: ...the Glycol Bath includes flash chill coils then follow these instructions for proper connections Locate Glycol Bath in line with convenient point along the trunk housings to splice into the product li...

Page 8: ...t line connections from trunk housing to dispensing head Pressurize lines to ensure that they are leak free After system start up tape product lines to coolant lines and re insulate product lines glui...

Page 9: ...thermostat has been factory programmed to cut out at 30 F with a hysteresis differential of 2 F Front Panel Commands Normal Operation SET To display target set point DEFROST To start a manual defrost...

Page 10: ...um Alarm Temperature has been exceeded for 15 minutes The Alarm will stop when temperature rises above the Minimum Alarm Temperature Causes of this alarm may include but are not limited to faulty cont...

Page 11: ...pose condenser Remove dirt from the fin surface using a brush vacuum or compressed gas COMPONENT RD060 RD120 Condensing Unit 3 4 HP 115V C22670 C22668 Drier R134A 3 8 ID inlet X 63297 63297 Valve Expa...

Page 12: ...le 63293 Junction Block 57946 Transformer Control 120 208 67510 Switch Single Pole Rocker 63303 Sensor NTC S ST 1 4 OD X 63816 2 Fitting Compression Brass 63296 3 Controller Digital XR20CX 67139 Wire...

Page 13: ...ommitted to continuous improvement Therefore we reserve the right to change specifications without prior notice 13 ARCTICPOUR Operation Installation Manual Form No Z2339 Rev 04 17 2018 RD060 Model Wir...

Page 14: ...Perlick is committed to continuous improvement Therefore we reserve the right to change specifications without prior notice 14 ARCTICPOUR Operation Installation Manual RD120 Model Wiring Diagram...

Page 15: ...PERATURE 11 12 CONTROL XR20CX SUPPLY 7 8 4 5 RELAY SENSOR 1 2 MTR PUMP TRANSFORMER P120V S24V 24 V CONTROL SIGNAL 1 2 MTR PUMP 1 2 MTR PUMP 1 2 MTR PUMP BLUE YELLOW RED ORANGE WHITE BLACK WHITE BLACK...

Page 16: ...t Good Hope Road Milwaukee WI 53223 Phone 414 353 7060 Fax 414 353 7069 Toll Free 800 558 5592 E Mail perlick perlick com www perlick com Form No Z2339 Rev 04 17 2018 inspires Quality Innovation that...

Reviews: