Page 1: ...IDS 409 SFP Hardware Installation Guide Managed Industrial Ethernet Switches Updated October 2016 Revision 1 10 Document Part 5500377 10 www perle com ...

Page 2: ...rference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this hardware guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to correct t...

Page 3: ... the IDS switch 16 Connecting Power to the IDS Switch 16 Wiring the Relay Alarm 17 Wiring Digital Inputs 18 Connecting the Console Port 19 Connecting Data Ports 21 SFP Connections 21 Resetting the Switch 22 Configuring the IDS Switch 25 Appendix A Technical Specifications 26 Appendix B Sample Labels 29 Appendix C Mechanical Drawings 30 Appendix D DIN Rail and Wall Mounting 34 Appendix E IDS Mainte...

Page 4: ... switch with attached DIN rail mounting bracket Quick Start Guide Document Conventions This document contains the following conventions Most text is presented in the typeface used in this paragraph Other typefaces are used to help you identify certain types of information The other typefaces are Note Means reader take note notes contain helpful suggestions Caution Means reader be careful In this s...

Page 5: ...models covered in this guide For more details and for the most up to date list of models please refer to the product pages at www perle com Standard Models 10 100 1000Base T Ports SFP Temp IDS 409 SFP 8 1 Standard IDS 409 2SFP 7 2 Standard IDS 409 3SFP 6 3 Standard IDS 409 5SFP 4 5 Standard IDS 409 SFP XT 8 1 Industrial IDS 409 2SFP XT 7 2 Industrial IDS 409 3SFP XT 6 3 Industrial IDS 409 5SFP XT ...

Page 6: ...S 409 SFP XT 1 Terminal Block for Power 1 2 8 Terminal Block Relay I O 2 Status LEDs 9 SFP Status LED 3 Console Port serial 10 SFP Slot 4 Console Port USB 11 Reset FS Fast Setup 5 DIP switches 12 Wall Mount Bracket Screw Holes 6 10 100 10100 Base T Ports 13 DIN Rail Clip 7 SD Card Slot ...

Page 7: ... Block for Power 1 2 8 SD Card Slot 2 Status LEDs 9 Terminal Block Relay I O 3 Console Port serial 10 10 100 1000 Base T Port 4 Console Port USB 11 SFP Slots 5 DIP switches 12 Reset FS Fast Setup 6 SFP Status LEDs 13 Wall Mount Bracket Screw Holes 7 10 100 1000 Base T Ports 14 DIN Rail Clip ...

Page 8: ... XT 1 Terminal Block for Power 1 2 8 SD Card Slot 2 Status LEDs 9 Terminal Block Relay I O 3 Console Port serial 10 SFP Slots 4 Console Port USB 11 Reset FS Fast Setup 5 DIP switches 12 Wall Mount Bracket Screw Holes 6 SFP Status LEDs 13 DIN Rail Clip 7 10 100 1000 Base T Ports ...

Page 9: ... XT 1 Terminal Block for Power 1 2 8 SD Card Slot 2 Status LEDs 9 Terminal Block Relay I O 3 Console Port serial 10 SFP Slots 4 Console Port USB 11 Reset FS Fast Setup 5 DIP switches 12 Wall Mount Bracket Screw Holes 6 SFP Status LEDs 13 DIN Rail Clip 7 10 100 1000 Base T Ports ...

Page 10: ...linking after power on System booting Green solid System ready operating normally Green blinking slowly Fast Setup Mode activated port available Green blinking fast Fast Setup Mode activated no port avail able Red Hardware fault or firmware load error State Description Off No alarms configured Green solid Alarms configured but no alarms detected Red solid Alarm condition detected Red blinking Alar...

Page 11: ... Ring Master not activated Green solid Ring Master Active redundant port blocked Coupling Link enabled Green flashing Ring Master unable to establish a ring due to missing link on one of the Ring ports Yellow solid Ring Master Active redundant port unblocked indi cates a break in the Ring ...

Page 12: ... switch s console This provides access to the switch management function using the industry standard CLI command set When connected the port presents a serial interface that can be used from a PC Terminal emulation program such as PuTTY Power Connector The power input connector has provisions for dual inputs Two independent power sources can be used to power the switch If one power input fails the...

Page 13: ...Speed Green and Yellow LEDs SFP Port Status Indicators Port Link State Description Green 1000 Mbps Green Yellow 100 Mbps Yellow 10 Mbps On solid Port Link Random blinking Port Link and Activity Slow blinking Error disabled Rapid blinking Port in Fast Setup Mode State Description Green Link Green Flashing Link Activity ...

Page 14: ...P Hardware Installation Guide Terminal Block Connectors P1 Power Input 1 P2 Power Input 2 IN 1 Digital Input 1 Dry Contact IN 2 Digital Input 2 Wet Contact R Relay with 2 connection points Normally Open NO Normally Closed NC ...

Page 15: ...itional parameters as well as the more advanced Ring features DIP Switch Ring Feature SW1 SW2 Ring Role Coupling Mode Description On On Software control Ring Master functionality is controlled by software configuration On Off Master Primary Ring Feature enabled Ring Role Master Coupling Active on Port 4 Note 1 Off On Client Standby Ring feature enabled Ring Role Client Coupling Backup on Port 4 No...

Page 16: ...P Hardware Installation Guide Port Assignment Note DIP switches are read during system boot up If a DIP switch is changed the IDS switch must be rebooted in order for the change to take effect Ring Ports 1 2 Coupling Port 4 ...

Page 17: ... protection characteristics in accordance with EN 60950 1 Warning The working voltage inputs are designed for operation with Safety extra low Voltage SELV Connect only to SELV circuits with voltage restrictions in line with IEC EN 60950 1 Hazardous Location Warnings Warning This equipment shall be installed in an enclosure that provides a degree of protection not less then IP54 in accordance with ...

Page 18: ...nect while the circuit is live or unless the area is free of ignit able concentrations Terminal Block Power Connectors Grounding the IDS switch If your installation requires additional grounding follow this procedure Grounding the chassis requires the following items One grounding lug not provided One 12AWG wire not provided Follow the manufacturers instructions for attaching the ground wire to th...

Page 19: ...rce is off prior to connection 2 Strip 2x12 20AWG 3 31 mm 0 52 mm twisted pair copper wires 7 8 mm 3 Loosen the terminal block screws and connect wires into theterminals 4 Tighten terminal screws Ensure the wires are securely fastened 5 Re insert the Terminal block connector if removed 6 Turn on power source Warning Ensure power has been removed at the source of the alarm circuit prior to pro ceed...

Page 20: ...52 mm twisted pair copper wires 7 8 mm 3 Loosen the terminal block screws and connect wires into theterminals For IN2 ensure that the live side of the input circuit is connected to the terminal and the return to the 4 Tighten terminal screws Ensure the wires are securely fastened 5 Re insert the Terminal block connector if removed 6 Turn on power source Warning Ensure power has been removed at the...

Page 21: ...nager Expand the Ports COM LPT section This will expand the drop down to show the number of com ports on your sys tem Connect the cable to one of these ports probably com1 or com2 4 Start an terminal emulation program such as Putty or SecureCRT on the COM port where you have connected the cable PC 5 Configure this COM port within the terminal emulation program with the following parameters 9600 ba...

Page 22: ...ars can be identified 4 Start an terminal emulation program such as Putty or SecureCRT on the com port where you have connect the cable to the PC 5 Configure your COM port within the emulation program on the PC as 9600 baud 8 data bits 1 stop bit No parity None flow control 6 The PC will display the bootloader sequence 7 Press Enter to display the setup prompt when the booting of the IDS is comple...

Page 23: ...ch Gigabit Ethernet requires CAT5 orbetter 2 Once the device is connected and link is established the link LEDs will turn on These LEDs willindicate whether you have a 10 100 or 1000 Mb s link to the switch See LED Indicators for moredetails Note It may take a few seconds for the device to become active By default the IDS switch will have Rapid Spanning Tree RSTP protocol enabled This protocol wil...

Page 24: ...ule is not equipped with a clasp then with your fore finger and thumb firmly grip the SFP and pull towards you Warning In hazardous location installations failure to remove the power from the source prior to removing the SFP modules from their slots could cause an electrical arc resulting in a possible explosion Note Changing the SFP to one that operates at a different speed ex 1000Mbps to 100Mbps...

Page 25: ...eleted The start up and backup software are unaffected Follow this procedure Power off the switch Press and hold the reset button While continuing to hold the reset button apply power to the switch ALR LED will go on after power up when it goes out release the reset button The switch is now reset to factory default configuration Booting the Switch When first applying power to the IDS switch it wil...

Page 26: ...ry default mode Refer to the Quick Start Guide that came with the switch for instructions on how to connect to the switch for the first time Password Recovery When the switch is not in factory default the Fast Setup Mode sequence will activate Password recovery Note The password recovery feature can be disabled in the software SYS Green blinking Boot process underway LED Behavior LED Behavior PWR ...

Page 27: ...rma tion Web Device Manager The Perle Web Device Manager is an embedded Web based application that provides an easy to use browser interface for managing the switch This interface provides the ability to configure and manage the switch This is accessible through any standard desktop web browser Requires the switch to have a valid IP address Fast Setup This utility provides the ability to do either...

Page 28: ...ed con tacts 1 0A 24VDC or 0 5A 48VDC Requires Class 2 LPS or SELV circuit with Fuse pro tection Digital Input IN1 Connects to Dry Contact Circuit Provides 12V 36mA On 2 1mA 4K Ohms Off 1 2mA 9K Ohms Digital Input IN2 Connect to Wet Contact Circuit requires external power Input Voltage Rating 36 to 36 VDC Input Impedance 4K Ohms On 10VDC Off 5VDC Rated Cable Temperatures IDS 409 SFP IDS 409 SFP XT...

Page 29: ...5 to 90 non condensing Storage Humidity Range 5 to 90 non condensing Operating Altitude Up to 3 048 meters 10 000 feet Standards and Certifications Safety UL 60950 1 IEC 60950 1 2005 A1 2009 and EN 60950 1 2006 A11 2009 A1 2010 A12 2011 CE Mark Industrial Safety UL 61010 1 and UL 61010 2 201 Formerly UL508 Emissions FCC 47 Part 15 Class A CISPR 22 2008 EN55022 2010 Class A CISPR 24 2010 EN 55024 2...

Page 30: ...ontact information for the Perle Technical Assistance Center PTAC can be found at the link below www perle com support_services support_request shtml Warranty Registration This product is covered by the Perle Ethernet Switches Warranty Details can be found at https www perle com support_services warranty shtml ...

Page 31: ...Appendix B Sample Labels 29 IDS 409 SFP Hardware Installation Guide Appendix B Sample Labels ...

Page 32: ...Appendix C Mechanical Drawings 30 IDS 409 SFP Hardware Installation Guide Appendix C Mechanical Drawings ...

Page 33: ...Appendix C Mechanical Drawings 31 IDS 409 SFP Hardware Installation Guide ...

Page 34: ...Appendix C Mechanical Drawings 32 IDS 409 SFP Hardware Installation Guide ...

Page 35: ...Appendix C Mechanical Drawings 33 IDS 409 SFP Hardware Installation Guide ...

Page 36: ...hooks of the DIN rail clip attach onto the top of the DINrail 3 Rotate the bottom of the IDS switch towards the rail This will snap the bottom hooks of the DIN rail cliponto the bottom of the DIN rail See diagram below Removing the IDS from the DIN Rail 1 The DIN rail attachment clip has a slot at the bottom of the latch that is visible beneath the switch when it is mounted 2 Insert a flat blade s...

Page 37: ...a guide to mark the spot where the screws will beplaced 4 Drive the screws into the wall leaving about 2 mm of the screw protruding from the wall to allow room for sliding the wall mount panel between the wall and the screws 5 Once the screws are fixed to the wall insert the four screw heads through the large parts of the keyhole shaped screw openings 6 Pull the IDS switch down to lock the IDS swi...

Page 38: ...ance of 50 8mm 2 inches on all sides of the IDS switch to pro vide proper airflowthrough the unit Do not use solvents or cleaning agents on this unit Keep vent holes clear of debris If case gets dirty wipe with a dry cloth Ensure all cables are in good working condition Replace any frayed cables or cables without clips ...

Page 39: ...DTE pinouts Ethernet Cables The 10 100 1000BaseT X ports located on the IDS switch s front panel are used to con nect to Ethernet enabled devices These Ethernet ports will automatically adjust depend ing on the type of Ethernet cable used straight through or cross over and the type of device NIC type or HUB Switch type connected to the port Requirements Cat 5 UTP or STP Cat 5e cables 24 22 AWG 0 2...

Page 40: ...rist strap or similar grounding device when handling transceiver modules Caution Do not install or remove SFP transceiver modules while fiber optic cables are still attached This can cause damage to the cables cable connectors and the optical inter faces It may also prevent the transceiver module from latching correctly into the socket connector Note Installing and removing SFP transceiver modules...