background image

IDS-306 Hardware Installation Guide

Managed Industrial Ethernet Switches

Updated: October 2019

Revision 1.1

Document Part#: 5500375-10

www.perle.com

Summary of Contents for IDS-306

Page 1: ...IDS 306 Hardware Installation Guide Managed Industrial Ethernet Switches Updated October 2019 Revision 1 1 Document Part 5500375 10 www perle com ...

Page 2: ...nce when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this hardware guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to correct the in...

Page 3: ... Connecting the Console Port 11 Connecting Destination Ports 12 Resetting the Switch 14 Booting the Switch 15 Fast Setup Mode 15 Password Recovery 15 Configuring the IDS Switch 16 Appendix A Technical Specifications 17 Appendix B Labels 19 Appendix C Mechanical Drawings 20 Appendix D IDS DIN Rail and Wall Mounting 21 Appendix E IDS Maintenance 23 Appendix F Cables and Connectors 24 ...

Page 4: ...nts IDS switch with attached DIN rail mounting bracket Quick Start Guide Document Conventions This document contains the following conventions Most text is presented in the typeface used in this paragraph Other typefaces are used to help you identify certain types of information The other typefaces are Note Means reader take note notes contain helpful suggestions Caution Means reader be careful In...

Page 5: ...tus Indicators The table below gives a brief overview of the models covered in this guide For more details and for the most up to date list of models please refer to the product pages at www perle com Standard Models Port 1 5 Port 6 Temp IDS 306 10 100 1000Base T RJ45 SFP slot Standard IDS 306 XT 10 100 1000Base T RJ45 SFP slot Industrial ...

Page 6: ...4 IDS 306 Hardware Installation Guide Switch Model View IDS 306 ...

Page 7: ... after power on System booting Green solid System ready operating normally Green blinking slowly Fast Setup Mode activated port available Green blinking fast Fast Setup Mode activated no port available Red Hardware fault or firmware load error State Description Off No alarms configured Green solid Alarms configured but no alarms detected Red solid Alarm condition detected Red blinking Alarm condit...

Page 8: ...ster Active redundant port blocked Coupling Link enabled Green flashing Ring Master unable to establish a ring due to missing link on one of the Ring ports Yellow solid Ring Master Active redundant port unblocked indicates a break in the Ring State Description Off Link Down Green flashing Link and activity Green blinking slowly Port in error disable or suspended state ...

Page 9: ...000 Mb s SFP Slots The SFP slots can accommodate industry standard SFP s from Perle or other suppliers These SFP s can be 100 or 1000 Mb s or can be SGMII models including 1000Base T Copper SFP s Power Connector The power input connector has provisions for dual inputs Two independent power sources can be used to power the switch If one power input fails the other power input will power the switch ...

Page 10: ...thernet Port Status Indicators Port Link Speed Green andYellow LEDs State Description Green 1000 Mbps Green Yellow 100 Mbps Yellow 10 Mbps On solid Port Link Random blinking Port Link and Activity Slow blinking Error disabled Rapid blinking Port in Fast Setup Mode ...

Page 11: ...g or office environment the device must be operated exclusively in switch cabinets with fire protection characteristics in accordance with EN 60950 1 Warning The working voltage inputs are designed for operation with Safety extra low Voltage SELV Connect only to SELV circuits with voltage restrictions in line with IEC EN 60950 1 Hazardous Location Warnings Warning This equipment shall be installed...

Page 12: ...Warning In case of malfunction or damage no attempts at repair should be made Do not dismantle the product All repairs need to be made by a qualified Perle representative Warning Explosion hazard Do not remove or replace lamps fuses or plug in modules as applicable unless power has been disconnected or the area is free of ignitable concentrations Warning Explosion hazard Do not disconnect while th...

Page 13: ...e IDS switch has a Normally Closed NC relay with terminals located on the top panel of the unit The IDS switch can be connected to an external powered device such as a siren or light for visual or audible notification of an alarm status 1 Ensure the power source is off prior to connection 2 Strip 2x12 20AWG 3 31 mm 0 52 mm twisted pair copper wires 7 8 mm 3 Loosen the terminal block screws and con...

Page 14: ...00 ports will automatically set themselves up to match the speeds of all attached devices If auto negotiation is not supported by one or more attached devices the ports can be configured to operate at fixed speeds and duplex settings Warning In hazardous location installations failure to remove the power from the source prior when completing the wiring connections to the Ethernet ports could cause...

Page 15: ...e connection s to the SFP slot s could cause an electrical arc resulting in a possible explosion Removing SFPs SFP modules are inserted in the SFP slots on the front of the IDS switch 1 Disconnect the fiber cable from the SFP module 2 If the SFP module is equipped with a clasp move it to the unlocked position and use the clasp to pull theSFP towards you 3 If the SFP module is not equipped with a c...

Page 16: ...will perform a complete power down and stay in the powered off state Press the reset button to power the switch on Reset to Factory Default Configuration The IDS 306 can be reset to the Factory default configuration When this is done all configuration user IDs passwords and security certificates are deleted The start up and backup software are unaffected Follow this procedure Power off the switch ...

Page 17: ... Start Guide that came with your IDS switch on how to connect to your switch for the first time Password Recovery When the switch is not in factory default the Fast Setup Mode sequence will activate Password recovery Note The password recovery feature can be disabled in the software LED Behavior PWR Yellow during the booting process Once the system software has been loaded the PWR LED will reflect...

Page 18: ...re information Web Device Manager The Perle Web Device Manager is an embedded Web based application that provides an easy to use browser interface for managing the switch This interface provides the ability to configure and manage the switch This is accessible through any standard desktop web browser Requires switch to have a valid IP address Fast Setup This utility provides the ability to do eith...

Page 19: ...J45 Industry standard RJ 45 connector SFP Port One SFP port Console RJ 45 connector LED Indicators PWR Power Inputs SYS System Status ALR Alarm BC For Future Use RM For Future Use 6 Fiber Port Link Activity Ports 1 G Y Link Activity Speed Reset FS Fast Setup switch Inset on front panel Terminal Block Rated at 105 C 221 F Environmental Operating Temperature Commercial Models IDS 306 Industrial Mode...

Page 20: ...UL 60950 1 EN 60950 EN IEC 60950 Industrial Safety UL 61010 1 UL 61010 2 201 EN 61010 1 EN 61010 2 201 EMI EMC FCC 47 Part 15 Class A CISPR22 2008 EN55022 2010 Class A CISPR 24 2010 EN55024 2010 Standard emissions FCC 47 Part 15 Class A CISPR 22 2008 EN55022 2010 Class A CISPR 24 2010EN 55024 2010 Hazloc Hazardous locations ANSI ISA 12 12 01 Class1 Division 2 Groups A D A TEX Class 1 Zone 2 Minimu...

Page 21: ...19 IDS 306 Hardware Installation Guide Appendix B Labels IDS 306 IDS 306 XT ...

Page 22: ...20 IDS 306 Hardware Installation Guide Appendix C Mechanical Drawings 5 port RJ 45 ...

Page 23: ... the DIN rail clip onto the bottom of the DIN rail See diagram below Removing the IDS from the DIN Rail 1 The DIN rail attachment clip has a slot at the bottom of the latch that is visible beneath the switch when it is mounted 2 Insert a flat blade screwdriver into the slot and twist the base to release the clip Alternatively a downward force on the clip will release the clip 3 When the clip is re...

Page 24: ... from the wall to allow room for sliding the wall mount panel between the wall and the screws 5 Once the screws are fixed to the wall insert the four screw heads through the large parts of the keyhole shaped screw openings 6 Pull the IDS switch down to lock the IDS switch to the wall mount 7 Tighten the four screws securely to the wall Note for best results use screws with the following attributes...

Page 25: ...2 inches on all sides of the IDS switch to provide proper airflowthrough the unit Do not use solvents or cleaning agents on this unit Keep vent holes clear of debris If case gets dirty wipe with a dry cloth Ensure all cables are in good working condition Replace any frayed cables or cables without clips ...

Page 26: ...evices These Ethernet ports will automatically adjust depending on the type of Ethernet cable used straight through or cross over and the type of device NIC type or HUB Switch type con nected to the port Requirements Cat 5 UTP or STP Cat 5e cables 24 22 AWG 0 20mm2 0 33mm2 Straight through or Ethernet Crossover cable Note An optional cable adapter is available to provide RJ45 to DB9 conversion Per...

Page 27: ...er modules while fiber optic cables are still attached This can cause damage to the cables cable connectors and the optical interfaces It may also prevent the transceiver module from latching correctly into the socket connector Note Installing and removing SFP transceiver modules can shorten their useful life Do not install or remove transceiver modules more than is necessary Warning This is a Cla...