General Specifications

Housing - Corrosion resistant polypropylene with 3” slip fittings. Fittings are also available in 2” & 2 1/2”.

Seal - Stationary type - Stainless Steel, with Buna trim for 5/8” shaft.

Motors - NEMA 56Y Frame

5976 SE Alexander Street, Suite F

Hillsboro, OR 97123  

P: 503-356-5888  F: 503-356-1660  

www.performancepropumps.com

WARNINGS

1. This pump and motor unit should be installed by a qualified electrician or serviceman in accordance with 

all applicable state and local codes and ordinances, and in accordance with the National 

  Electrical Code.  Improper installation may create a mechanical or electrical hazard which could cause 

damage to property and which could result in serious injury or death.  Always follow the schematic on 

the motor for all electrical connections!

2.  In order to avoid serious injury or death, always disconnect power to the motor before servicing the 

pump.

3.  Never run the pump dry.  You must fill the priming pot (volute) with water before starting the motor.

4.  Never start the pump when the motor shaft is turning.  To prevent unwanted motor rotation, install a 

swing type check valve.

5.  If you are not competent to install the pump, get help from a qualified source.

6.  Maintain a minimum flow rate of two gallons per minute.

7.  Visually inspect the pump and motor once a month.  If there is any leakage 

  from the shaft seal, replace it at once. The seal faces wear 

  (just like car tires) and must be replaced periodically. For critical

  applications, replace the shaft seal yearly.

8.  For 3 phase motors, insure correct motor rotation. See item 7 in 

  electrical for details.

Summary of Contents for ArtesianPro

Page 1: ...ion may create a mechanical or electrical hazard which could cause damage to property and which could result in serious injury or death Always follow the schematic on the motor for all electrical connections 2 In order to avoid serious injury or death always disconnect power to the motor before servicing the pump 3 Never run the pump dry You must fill the priming pot volute with water before start...

Page 2: ...ousing and diffuser from the pump then connect the power and check rotation If it is incorrect exchange any two of the connected leads and retest When the rotation is correct reinstall the diffuser and volute Never test rotation by bumping a connected electrical switch This will destroy the pump and void the warranty Installation General Proper installation of your ArtesianPro pump will help insur...

Page 3: ...depending on the motor design and unscrew the impeller by turning it counter clockwise 8 Loosen and remove the four 3 8 M bolts that hold the bracket to the motor face 9 If you wish to remove the shaft seal place the bracket face down on a flat surface and press out the carbon spring seal from the back side Never pry it out from the front Carefully remove the ceramic from the back impeller hub wit...

Page 4: ...imers exclusions of or limitations on how long an implied warranty lasts so in such States and except as is otherwise provided by applicable law of said States no action on a warranty implied at law shall be commenced more than one year following the date of purchase No action shall be brought for breach of any express warranty subsequent to the expiration of the express written warranty 7 Inciden...

Page 5: ...T TO PRIME AP 1 4 66 3 FEET 8 MINUTES AP 1 3 73 4 FEET 8 MINUTES AP 1 2 92 7 FEET 8 MINUTES AP 3 4 112 9 FEET 7 MINUTES AP 1 130 9 FEET 6 MINUTES AP 1 2 HF 5 FEET 8 MINUTES AP 3 4 HF 8 FEET 8 MINUTES AP 1 HF 9 FEET 8 MINUTES AP 1 1 2 HF 9 FEET 7 MINUTES AP 2 HF 9 FEET 6 MINUTES AP 3 HF 9 FEET 5 MINUTES AP 5 HF 9 FEET 5 MINUTES AP 1 HH 7 FEET 6 MINUTES AP 1 1 2 HH 8 FEET 6 MINUTES AP 2 HH 9 FEET 6 ...

Page 6: ...ws how to wire a typical Baldor 1 4HP Single Phase 1725 RPM motor with the following diagram LOW VOLTAGE 115V LINE A LINE B TOGETHER 1 3 4 2 J HIGH VOLTAGE 230V LINE A LINE B TOGETHER TAPE 1 4 2 3 J CONNECTIONS ABOVE GIVE CLOCKWISE ROTATION FACING LEAD END For low voltage 1 Connect your incoming hot lead normally the black wire to the wires marked 1 and 3 2 Connect your incoming neutral lead norma...