Electrical Characteristics
Juno Step Motor Control IC User Guide
21
3
3.2.2
SPI
3.2.3
Power-on Reset
Note: The device will generate a
~Reset
pulse upon power on. An external
~Reset
signal is optional.
3.2.4
Warm Reset
3.2.5
Pulse & Direction
Timing Interval
No.
Min
Max
SPIClock clock cycle time
T23
80 nSec
Pulse duration, SPIClock high
T24
33 nSec
Pulse duration, SPIClock low
T25
33 nSec
~SPIEnable low to first SPIClock high
T26
25
SPIClock high to SPIXmt valid delay time
T27
21 nSec
SPIXmt data valid time after SPIClock low
T28
T25
SPIRcv setup time before SPIClock high
T29
25 nSec
SPIRcv valid time after SPIClock low
T30
25 nSec
Last SPIClock low to ~SPIEnable high
T31
25
Timing Interval
No.
Min
Max
Power on pulse duration driven by device (typical) (note 1)
T32
600
μ
Sec
Device ready/ outputs initialized (typical)
T33
2 mSec
Timing Interval
No.
Min
Max
~Reset low duration for warm reset
T35
570 nSec
Timing Interval
No.
Min
Max
Pulse frequency
1.0 Mhz
Pulse width
T38
50 nSec
Direction setup time before pulse low
T39
26 nSec
Direction valid time after pulse low
T40