background image

Perfect Aire, LLC
5401 Dansher Road
Countryside, IL 60525

Distributed by:

844-4PA-AIRE  |  844-472-2473

www.perfectaire.us

WINDOW

AIR CONDITIONER

FOR MODEL: 

5PAC6000
5PAC8000

Before using your air conditioner, please 
read this manual carefully and keep it for 
future reference, along with your receipt.

Specification and performance data is subject to change without notice.

Printed in China

PA/User_5PAC6000_5PAC8000/10242019

USER MANUAL

Summary of Contents for 5PAC6000

Page 1: ...WINDOW AIR CONDITIONER FOR MODEL 5PAC6000 5PAC8000 Before using your air conditioner please read this manual carefully and keep it for future reference along with your receipt USER MANUAL...

Page 2: ...___________________________ Purchase Date _____________________________________ Store Purchased ______________________________________ Installation Date ____________________________________ Installati...

Page 3: ...ller for installation of this unit The air conditioner is not intended for use by young children without adult supervision Young children should be supervised to ensure that they do not play with the...

Page 4: ...the unit Failure to do so may cause fire and electric shock DO NOT use the socket if it is loose or damaged Doing so may cause fire and electric shock DO NOT open the unit during operation Doing so m...

Page 5: ...d of time unplug or turn OFF main power switch Leaving power on may cause unit failure or fire Do not place obstacles around air inlets or inside of air outlet Obstacles may cause appliance failure or...

Page 6: ...sure the air conditioner has been securely and correctly installed according to the installation instructions in this manual Save this manual for possible future use in removing or installing this un...

Page 7: ...e power cord of the air conditioner Aluminum house wiring may present special problems consult a qualified electrician When handling unit be careful to avoid cuts from sharp metal edges and aluminum f...

Page 8: ...pcs C Align the hole in the top rail with those in the top of the unit as shown in Fig B D Secure the top rail to the unit with the 3 8 screws as shown in Fig C NOTE For safety reasons all four 4 scr...

Page 9: ...r is tilted back approximately 3 4 to 1 Fig 5 above tilted about 3 to 4 downward to the outside If after proper installation condensation does not drain from the overflow drain hole during normal use...

Page 10: ...ter the unit is installed in the window measure the inner width of one of the accordion panels as shown in Fig 11 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 2 3 4 5 6 STEP 6 2 Mark a line on one of t...

Page 11: ...caulked or painted shut Accumulated rain water or condensation must be allowed to drain out FIG 15 Sash Storm window frame or other obstruction 1 min 38 mm Board thickness as required for proper pitch...

Page 12: ...ng the unit This unit can be controlled by the unit control or with the remote control FOLLOW ME Indicator Energy Saver Mode Sets Mode Sleep Mode Turns Unit On or Off Set Fan Speed Adjusts Temp or Tim...

Page 13: ...goes from AUTO COOL DRY and FAN The indicator light will be illuminated and remain on once the mode is selected The unit will automatically initiate the Energy Saver function under COOL DRY and AUTO...

Page 14: ...ally when the power resumes AIR DIRECTIONAL LOUVERS Use the 4 way directional louvers to direct the air flow up or down and left or right throughout the room as needed Pivot horizontal louvers until t...

Page 15: ...hot water over 104 F 40 C to clean the air filter Never attempt to operate the unit without the air filter CABINET CLEANING Be sure to unplug the air conditioner to prevent shock or fire hazard The c...

Page 16: ...oil set to FAN only mode Then set temperature to a higher setting AIR CONDITIONER CYCLING ON AND OFF TOO FREQUENTLY OR NOT ENOUGH Be sure unit is not too large or too small for the area of the room Re...

Page 17: ......

Page 18: ......

Page 19: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details...

Page 20: ...01 Dansher Road Countryside IL 60525 Distributed by 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User_5PAC600...

Reviews: