7

EJECTOR PUMP DRAINAGE

 TO USE THE PUMP DRAINING OPTION

INSTALLATION:

1.  Attach the pump hose adapter to the 16 ft. clear hose 

(both included with the unit).

2.  Connect the pump drainage adapter (#1 in the 

diagram) to the drain hole located on the bottom left 

back of the unit (#2 in the diagram).

3.  When unit’s internal tray capacity reaches the  

pre-determined water level, the unit will  

pump automatically.

 

DISASSEMBLY:

1.  Press and hold the ribbed circle found above the 

adapter (#3 in diagram) on the unit.

2.  The continuous drainage adapter will release.
3.  Gently pull the adapter with the holes away from the 

unit while continuing to press on the ribbed circle.

4.  Rinse the hose and the adapter by running water 

through both before storing in a safe place.

3

2

1

NOTE:

 Hose may be cut shorter if needed 

depending on draining distance.

Summary of Contents for 1PEDP50

Page 1: ...OR MODELS 1PEDP50 1PEDP70 Before using your dehumidifier please read this manual carefully and keep it for future reference along with your receipt USER MANUAL Be sure to read the QUICK START TIPS on...

Page 2: ...___________________________ Purchase Date _____________________________________ Store Purchased ______________________________________ Installation Date ____________________________________ Installati...

Page 3: ...acking the dehumidifier note that the foam inside the float piece in the bucket should NOT be removed Without this foam piece the dehumidifier will not operate properly and water can overflow NOTE Rem...

Page 4: ......

Page 5: ...otection against shock hazards DO NOT remove the third prong The unit must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protect...

Page 6: ...plug with wet hands CAUTIONS DO NOT place anything on top of the unit DO NOT place anything over the air inlet or outlet grilles DO NOT let children play by or with the unit DO NOT get any liquid on...

Page 7: ...NOT place the machine on an uneven ground Always keep the unit 8 inches 30 cm away from the wall to dissipate the heat properly 8 It is dangerous to pour anything into the machine Close all open wind...

Page 8: ...ions and functions are the same Handle Moist Air Intake Dry Air Vent Control Panel Water Bucket Air Filter found behind the grille Roll Casters Continuous Drainage Outlet Pump Outlet WHAT IS THE FLOAT...

Page 9: ...UMIDITY TIMER HUMIDITY SET DISPLAY When the unit is running it displays the current humidity Press TIMER pad the set hours are displayed here Ten 10 seconds after displaying the timer the display will...

Page 10: ...the bucket is full the unit will stop running beep 5 times and the BUCKET FULL light will illuminate To empty the bucket carefully slide the bucket out from the bottom front of the unit Hold the bucke...

Page 11: ...topper 4 Return the bucket to its proper position Bucket Store Rubber Stopper and Drain Hose in Bucket 5 Insert the drain hose provided through the hole of the drain cover with the washer portion on t...

Page 12: ...tray capacity reaches the pre determined water level the unit will pump automatically DISASSEMBLY 1 Press and hold the ribbed circle found above the adapter 3 in diagram on the unit 2 The continuous...

Page 13: ...he dehumidifier to avoid splashing water onto in the unit Partially fill the bucket with clean water and add a small amount of mild detergent Swish it around in the bucket empty and rinse NOTE DO NOT...

Page 14: ...sure unit is level and that there are no curtains blinds or furniture blocking the unit Check that room temperature is 41 F or above If unit is near a heat source such as a clothes dryer etc relocate...

Page 15: ...back of unit and always be positioned at a DOWNWARD slope to the desired drain location Check that filter vents and bucket are thoroughly clean Be sure nothing is obstructing hose connection and there...

Page 16: ...Belt Line Rd Suite 878 Dallas TX 75254 Distributed by 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User_1PED...