Assembly and Operation Manual 

Appendix A Control signal algorithm at pulse control mode 

The following commands can be formed by sending a low-level signal to the contacts 

Unlock A

Stop

 and 

Unlock

 

B

 of the 

XT1.L

 connector block relatively to the contact 

GND

 

(The command is a signal active front (signal transfer from the high level to the low level) 
at any of the contacts at presence of the corresponding signal levels at the other contacts): 

Always locked (closed for entry and exit) - 

Active front is at contact 

Stop

 while there is a high level at contacts 

Unlock

 

A

 and  

Unlock

 

B

Both passage directions get closed at this command. 

Single passage in direction A (open for passage of one person in direction A) - 

Active front is at contact 

Unlock A

 while there is a high level at contacts 

Stop

 and  

Unlock

 

B

At this command passage direction A opens either for 5 sec. or until the passage has been 
made in this direction or until the command 

“Always locked”

, and the status of passage 

direction B does not change. The command is ignored if at the moment of its receipt the 
status of passage direction A was 

“Always free”

Single passage in direction B (open for passage of one person in direction B) - 

Active front is at contact 

Unlock B

 while there is a high level at contacts 

Stop

 and  

Unlock

 

A

At this command passage direction B opens either for 5 sec. or until the passage has been 
effected in this direction or until the command 

“Always

 

locked”

, and the status of 

passage direction A does not change. The command is ignored if at the moment of its 
receipt the status of passage direction B was “

Always free”

Single passage in both directions (open for single passage of one person at a time 

in each direction) - 

Active front is at contact 

Unlock A

 while there is a low level at contact 

Unlock

 

B

 and a high 

level at contact 

Stop

or active front is at contact 

Unlock

 

B

 while there is a low level at contact 

Unlock

 

A

 and a 

high level at contact 

Stop

At this command the both passage directions open either for 5 sec. each or until the 
command “

Always locked”

 is received. The command is ignored for the passage 

direction, which status at the moment of its receipt was “

Always free”

Free passage in direction A (open for free passage in direction A) - 

Active front is at contact 

Unlock A

 while there is a low level at contact 

Stop

 and a high 

level at contact 

Unlock

 

B

or active front is at contact 

Stop

 while there is a low level at contact 

Unlock

 

A

 and a high 

level at contact 

Unlock

 

B

At this command passage direction A opens until the command 

“Always locked” 

is 

received and the status of passage direction B does not change. 

Free passage in direction B (open for free passage in direction B) - 

Active front is at contact 

Unlock B

 while there is a low level at contact 

Stop

 and a high 

level at contact 

Unlock A

or active front at contact 

Stop

 while there is a low level at contact 

Unlock

 

B

 and a high 

level at contact 

Unlock

 

A

28 

Summary of Contents for TTR-04CW

Page 1: ...ASSEMBLY AND OPERATION MANUAL TTR 04CW Electromechanical Tripod Turnstile...

Page 2: ...Electromechanical Tripod Turnstile TTR 04CW Assembly and Operation Manual...

Page 3: ...ide control 17 5 11 Operation contingencies and response 17 6 MARKING AND PACKAGING 18 7 SAFETY REQUIREMENTS 18 7 1 Installation safety requirements 18 7 2 Operation safety requirements 18 8 INSTALLAT...

Page 4: ...ties banks administrative buildings retail outlets railway terminals airports etc To ensure fast and convenient passage it is recommended to install one turnstile per 500 people working the same shift...

Page 5: ...8 5 of the heating system with thermocontrol max 60 Throughput rate in the single passage mode 30 persons min in a free passage mode 60 persons min Passageway width 600 mm Barrier arm rotation force m...

Page 6: ...ertificate 1 Operation manual 1 Packaging Box 1 4 2 Optional equipment supplied on request Turnstile power supply 1 Power supply of the heating system 24 ACV 1 WRC kit2 1 Intrusion detector 1 Siren fo...

Page 7: ...M8 for mounting the barrier arm 7 AC power cables1 8 turnstile power supply unit1 9 turnstile power cable1 10 RC panel WRC1 ACS controller 1 11 cable of the RC panel WRC ACS controller 1 12 anchor bol...

Page 8: ...ing to ensure accurate count of inputs to an ACS The turnstile is supplied with safe voltage maximum 14 V with the heating system with thermocontrol in operation no more than 40 V The turnstile has lo...

Page 9: ...e RC panel is connected to the CLB with a multicore cable 11 via the XT1 L connector block See Fig 4 Figure 4 RC panel overall view 1 2 3 buttons LEFT RIGHT STOP for setting the passage mode 4 5 green...

Page 10: ...tains X1 Control connector to connect the control mechanism connected to the X1 connector of the control mechanism with the turnstile cable XT1 L In connector block to connect the RC panel WRC inputs...

Page 11: ...Assembly and Operation Manual Figure 6 Connection layout 10...

Page 12: ...ove devices can be connected to the turnstile as follows any device separately in any combination with each other all devices simultaneously in parallel Note At the parallel connection of the above de...

Page 13: ...re Alarm contact relatively to the GND contact As the control element there can be used a normally closed relay contact or a circuit with open collector output at that Fig 7 and 8 Note For generating...

Page 14: ...f the turnstile control a pulse control mode and a potential control mode They determine available operating modes of the turnstile Table 2 and Table 3 5 5 2 The control mode is set by the jumper on t...

Page 15: ...dix B The minimum input signal duration when the operating mode can be changed should be 100 msec The passage waiting time is equal to the low level signal duration the turnstile remains open in the s...

Page 16: ...peration with ACS controller 5 8 1 In the pulse control mode control over the turnstile with an ACS controller is similar to that with the RC panel 5 8 2 In the potential control mode control over the...

Page 17: ...signal absence Other control commands are ignored at that When the low level signal appears at the Fire Alarm input the turnstile turns to the Always locked mode 5 9 3 2 In the potential control mode...

Page 18: ...ial signal Ready is generated in each of the above cases 5 11 2 2 In case of unauthorized access the Ready signal is formed as follows at 8 arm rotation one of the optical sensors Fig 13 responds and...

Page 19: ...the turnstile Chapter 4 1 is packed in a transportation box which keeps it undamaged during the transportation and storage Box overall dimensions length width height 114 32 32 cm Gross weight max 42 k...

Page 20: ...ccount that the resetting device operates as follows at the barrier arm turning at the angle of more than 60 the reset is effected in the direction of movement at the barrier arm turning at the angle...

Page 21: ...he CLB connectors location is shown in Fig 5 Cables parameters and their length are given in clause 8 3 The installation surface and passage area recommendations are given in clause 8 1 1 Unpack the t...

Page 22: ...horizontal plane using hook and loop cable ties 14 Connect S1 and S2 cable connectors connecting the indication board of the cover with the board in the housing Mount the cover with LED indication ba...

Page 23: ...the heating and the temperature indication turns off 4 Check operation of the intrusion detector and siren if included in the delivery set and installed accordingly After the power up wait until the m...

Page 24: ...arrow pictograms left and right are on The turnstile is locked in the direction of completed passage 4 Free passage in the set direction open for free passage in the chosen direction Press the STOP bu...

Page 25: ...h for entry and exit The high level on contacts Unlock A and Unlock B or low level on the contact Stop The red indicator above the STOP button is on The Red cross pictogram is on The turnstile is lock...

Page 26: ...anufacturer or his representatives only Table 4 Possible faults and remedy Fault Possible cause Remedy At the power up the turnstile won t work and there is no light indication on the turnstile housin...

Page 27: ...he rotation axis of the pusher two on the fastening axis of the springs holes in the fastening parts of the springs lock cylinder of the mechanical lock 15 through the keyhole Note Avoid the ingress o...

Page 28: ...and transportation the boxes can be stacked no more than 4 layers high The storage of the turnstile is allowed indoors at ambient temperature from 40 C to 50 C and at relative air humidity up to 75 at...

Page 29: ...e passage has been effected in this direction or until the command Always locked and the status of passage direction A does not change The command is ignored if at the moment of its receipt the status...

Page 30: ...ons close at this command Direction A is open open for passage in direction A There is a low level at contact Unlock A while a high level is present at contacts Stop and Unlock B At this command direc...

Page 31: ......

Page 32: ......

Page 33: ...PERCo Polytechnicheskaya str 4 block 2 194021 Saint Petersburg Russia Tel 7 812 247 04 64 E mail export perco com support perco com www perco com...

Page 34: ...www perco com...

Reviews:

Related manuals for TTR-04CW