TTR-04CW Electromechanical Tripod Turnstile
At this command passage direction B opens until the command
“Always locked”
is
received and the status of passage direction A does not change.
Free passage (open for passage in both directions) -
Active front is at contact
Unlock A
while there is a low level at contacts
Unlock
B
and
Stop
,
or active front is at contact
Unlock
B
while there is a low level at contacts Unl
oc
k
A
and
Stop
,
or active front is at contact
Stop
while there is a low level at contacts
Unlock
A
and
Unlock
B
.
The both directions open at this command until the command
“Always locked”
is
received.
Note! For the RC panel:
active front — pressing of the relevant button on the RC panel;
low level — the relevant button on the RC panel has been pressed;
high level — the relevant button on the RC panel has not been pressed.
Appendix B Control signal algorithm at potential control mode
Both directions are closed (closed for entry and exit) -
There is a high level at contacts
Unlock
A
and
Unlock
B
or there is a low level at contact
Stop
.
The both passage directions close at this command.
Direction A is open (open for passage in direction A) -
There is a low level at contact
Unlock
A
while a high level is present at contacts
Stop
and
Unlock
B.
At this command direction A opens up to the elimination of low-level signal from contact A
or until the command “Both directions closed” is received, and the status of direction B
does not change.
Direction B is open (open for passage in direction B) -
There is a low level at contact
Unlock B
while there is a high level at contacts
Stop
and
Unlock A
.
At this command direction B opens up to the elimination of low-level signal from contact B
or until the command “Both directions closed” is received, and the status of direction A
does not change.
Both directions are open (open for entry and exit) -
There is a low level at contacts
Unlock A
and
Unlock B
while there is a high level at
contact
Stop
.
The both directions open at this command up to the elimination of low-level signal from
one of the contacts A (B) or until the command “Both directions closed” is received.
Note! For an ACS controller outputs:
low level — either contacts of the output relay are closed or the output transistor
is open;
high level — either contacts of the output relay are broken or the output transistor
is closed.
29
Summary of Contents for TTR-04CW
Page 1: ...ASSEMBLY AND OPERATION MANUAL TTR 04CW Electromechanical Tripod Turnstile...
Page 2: ...Electromechanical Tripod Turnstile TTR 04CW Assembly and Operation Manual...
Page 11: ...Assembly and Operation Manual Figure 6 Connection layout 10...
Page 31: ......
Page 32: ......
Page 34: ...www perco com...