TTD-03.2 Electromechanical Box Tripod Turnstile
17
17. Control the turnstile housing and barrier arms fastening, check serviceability and accuracy of
all the electrical connections.
18. Run a test switching-on of the turnstile as specified in Chapter 10. Check operation of the
intrusion detector and the siren (if included in the delivery set).
19. After the power-up wait until the moment of the test indicator (inside the intrusion detector)
going off (from 10 to 50 sec, the turnstile should be in the “Always locked” mode (at the pulse
control mode) or in the "Both directions closed" (at the potential control mode)).
20. Put your hand before the intrusion detector. The continuous signal will sound when the
intrusion detector activates. To eliminate that sound signal, press any button on the RC panel.
The sound will stop without pressing the button in 5±0.5 sec.
Once the installation has been completed, the turnstile is ready for operation.
8.5 Connection layout
Fig. 12. Connection layout