Assembly and Operation Manual
9 OPERATION
Follow the instructions of speed gate operation in accordance with Sect. 7.2.
Attention!
Do not move through the speed gate passage area any objects with dimensions
exceeding the width of the passage lane.
Do not jerk and hit any elements of the speed gate to prevent their mechanical
deformation.
Do not dismantle or adjust mechanisms, ensuring the speed gate operation.
Do not use substances that may cause mechanical damage or corrosion of the surface
for speed gate cleaning.
9.1 Power-up
Attention!
Before speed gate power-up make sure that the passage lane is free and nothing interferes
with the swing panels movement.
In order to power up the speed gate, proceed as follows:
1. Connect the speed gate power supply unit to the AC outlet with the voltage and frequency
rating complying with the certificate for the power supply unit.
2. Switch on the speed gate power supply unit. Speed gate swing panels get automatically set
into an initial (locked) position.
3. At pulse control mode the
“Always locked”
command
is sent automatically, at the potential
control mode –
“Always locked”
command is sent automatically
(Tables 7 and 8) until another
command is sent from the external controller. The speed gate is ready for operation.
9.2 Pulse control mode
Speed gate control command sending from the RC-panel and its indication on the speed gate
sections is performed in accordance with Table 7. Passage directions are independent of each
other, i.e. sending a command for one direction, doesn’t change the opposite direction mode.
Table 7. Pulse control mode
Indication
Command
RC-panel operator
actions
RC-panel
Central post
Speed gate state
“Always
locked”
Press the
STOP
button
Red
“Stop”
indicator
is on
Red for both
directions
The swing panels
are closed
“Single
passage in a
set direction”
Press the
LEFT
/
RIGHT
buttons
Red
“Stop”
indicator
is on and the green
indicator for the set
direction
“Left”
/
“Right”
is on
Green for the
set direction
The swing panels
turn in the passage
direction
“Free passage
in a set
direction”
Press both
STOP
and
LEFT
/
RIGHT
buttons
simultaneously.
Green indicator of the
set direction
“Left”
/
“Right”
is on
Green for the
set direction
The swing panels
are open in the free
passage direction
until receiving the
next command
“Free
passage”
Press all three
LEFT
,
STOP
and
RIGHT
buttons
simultaneously
Both green indicators
“Left”
and
“Right”
are
on
Green for
both
directions
Swing panels are
open until receiving
the next command
RC-panel buttons and indicators are shown in Fig. 8.
1
Speed gate control from the WRC is the same as the control from the RC-panel. Buttons on the WRC fob
control the same functions as the RC-panel buttons.
40