Assembly and Operation Manual
3 TECHNICAL SPECIFICATIONS
Operating voltage
......................................................................................................... 24±2.4 VDC
Current consumption
..........................................................................................................
max.
6.5 A
Power consumption
...................................................................................................... max. 160 W
Throughput rate in a single passage mode ............................................................. 60 persons / min
Passageway width
:
with
ATG-300, ATG-300H
swing panel ............................................................................ 650 mm
with
ATG-425
swing panel ............................................................................................... 900 mm
with
ATG-475
swing panel ............................................................................................. 1000 mm
Number of intrusion detectors:
upper level ................................................................................................................................. 14
lower level ................................................................................................................................. 28
RC-panel cable length
..................................................................................................... min. 6.6 m
IP rating ................................................................................................................... IP41 (EN 60529)
Electric shock protection class.................................................................................... III (IEC 61140)
Mean time to failure
................................................................................... min. 5,000,000 passages
Mean lifetime .......................................................................................................................... 8 years
Overall dimensions
(L × W × H):
with
ATG-300
swing panel
........................................................................ 1820×1050×1010 mm
with
ATG-300H
swing panel
...................................................................... 1820×1050×1300 mm
with
ATG-425
swing panel
........................................................................ 1820×1300×1010 mm
with
ATG-475
swing panel
........................................................................ 1820×1400×1010 mm
Note:
Use the following formula to calculate the overall speed gate width in case several passage
lanes are arranged (Fig. 5):
L
overall
= 920 n + 1170 m +1270 k +130
(mm), where:
n
– number of
ATG-300
and
ATG-300H
swing panel sets installed;
m
– number of
ATG-425
swing panel sets installed;
k
– number of
ATG-475
swing panel sets installed.
Weight (net):
ST-01/M
section ............................................................................................................ max 85 kg
ST-01/S
section ............................................................................................................ max 85 kg
STD-01
double-sided section ..................................................................................... max 100 kg
ATG-300
swing panel
..................................................................................................... max 6 kg
ATG-300H
swing panel
.................................................................................................. max 9 kg
ATG-425
swing panel
..................................................................................................... max 8 kg
ATG-475
swing panel
..................................................................................................... max 9 kg
4 DELIVERY SET
4.1 Standard delivery set
4.1.1
ST-01
Speed gate
Main equipment:
ST-01/M
(
Master
)
section ........................................................................................ 1 (in box #1)
ST-01/S
(
Slave
)
1
section ........................................................................................... 1 (in box #2)
Section top cover .......................................................................................... 2 (in a separate box)
The power supply is connected to the control board located in the
Master
section (on the
Master
side of
the double-sided section) and has the
“ST-01.771”
marking
.
Current consumption and power consumption are given for each product
ST-01
and
STD-01
individually.
Maximum allowable cable length of the RC panel is 40 m (supplied upon request).
Overall dimensions of the speed gate with different types of panels are shown in Fig. 1, 2, 3, 4, 5.
Both sections are delivered with disassembled top covers, panels, panel cover plates and central
indication blocks.
4