Operation Manual
8
Contact Contact name in the
Web-interface
Designation
XT7 (OUT2 )
connector
NO2
NO2/C2/NC2
normally open contact
“Relay control output OD #2” or
“Additional output OUT #2”
C2
central contact
NC2
normally closed contact
XT8 (OUT3)
connector
NO3
NO3/C3/NC3
normally open contact
“Relay control output OD #3” or
“Additional output OUT #3”
C3
central contact
NC3
normally closed contact
XT9 (OUT4)
connector
NO4
NO4/C4/NC4
normally open contact
“Relay control output OD #4” or
“Additional output OUT #4”
C4
central contact
NC4
normally closed contact
XT10 (RC2)
connector
GND
–
“Common”
DUA
DUA 2
“Control input of the OD3 from the RC-button” or “Control input of
direction A from the RC-panel #2” or “Additional input IN #10”
DUSt
DUSt 2
“Input STOP from the RC-panel #1” or “Additional input IN #11”
DUB
DUB 2
“Control input of the OD4 from the RC-button” or “Control input of
direction B from the RC-panel #2” or “Additional input IN #12”
LdA
LdA 2
“Output for indication of direction A on the RC-panel #2”
LdSt
LdSt 2
“Output for indication STOP on the RC-panel #2”
LdB
LdB 2
“Output for indication of direction B on the RC-panel #2”
5.3 IP-address setting
The way of IP-address setting is selected by installing or removing the jumper on
XP1
connector
on the controller upper board.
Following ways of IP-address setting are possible (see Table 2):
1. User mode. Jumper is removed.
•
If the user does not change the IP-address (gateway, subnet mask), the controller operates
with default settings: IP-address and MAC-address are specified in the certificate of IP-stile
and on the controller board; subnet mask is
255.0.0.0
; gateway
IP-address is
0.0.0.0
.
•
If the user changes the IP-address (gateway, subnet mask), the controller starts operating
with the new settings immediately without switching the power supply.
Note:
It is possible to change network settings of the controller on PC via Web-interface or
software. The controller and PC must be on the same subnet.
2.
“IP MODE”.
Jumper is in the position 1–2.
•
Operation in networks with dynamic allocation of IP-addresses, the controller can receive
IP-address (gateway, subnet mask) from DHCP-server.
3.
“IP DEFAULT”.
Jumper is in the position 2–3.
•
The controller operates with default settings: IP-address and MAC-address are specified in
the certificate of IP-stile and on the controller board; subnet mask is
255.0.0.0
; gateway
IP-address is
0.0.0.0
.
•
To access the controller, the password is not required. Installing the jumper into the
“IP
DEFAULT”
mode allows changing the password.
Note:
User settings of IP-address (gateway, subnet mask), if they were set, are saved during the
switch into
“IP DEFAULT”
mode. The controller will operate with them at next turn-on, if
jumper is not installed.