CT/L-14 Controller Web-Interface 

39 

On the page the user can select the following elements: 

1.  The  page  title bar contains 

PERCo

  trademark and buttons to select the language of Web-

interface. By clicking on the 

PERCo

  company logo the user will  navigate to the main page 

from other sections of Web-interface. 

2.  Sidebar of the Web-interface navigation. The panel has the following structure: 

“Settings” 

“Time” 

 

“Network” 

 

“Server” 

 

“Password” 

 

“Cards format” 

 

“Configuration” 

“Template” 

 

“Edit” 

“Operating devices” 

“Physical contacts” 

“Readers” 

“Internal responses” 

“Events filters” 

“Access” 

“Time access criteria” 

 

 

 

 

“Time zones” 

“Holidays” 

“Weekly schedule” 

“Shift-day” 

“Flexible weekly” 

“Users” 

 

“Operating device control”   

 

“Events” 

 

 

“Status” 

 

 

“Service” 

 

 

3.  Page working area. 

3.  SETTINGS 

3.1  Change of controller system time  

To change the time: 

1.  Click 

Settings 

  Time

  in the Web-interface menu

The page with working area will be 

opened:  

 

2.  In the 

Date

,

 Time

 input fields change the set values. 

3.  Select the desired value for the 

Time Zone

 parameter. 

4.  If necessary, tick the 

Synchronize with PC 

box

 

to synchronize the time and date of the 

controller with the computer connected to the Web-interface. 

5.  Click the 

Save

 button. 

Summary of Contents for CT/L-14

Page 1: ...Controller CT L 14 ASSEMBLY AND OPERATION MANUAL...

Page 2: ...CT L 14 Controller Assembly Operation Manual...

Page 3: ...13 8 2 Installation order 14 8 2 1 Controller installation 14 8 2 2 Door control configuration 16 8 2 3 Turnstile and electromechanical gates configuration 18 8 2 4 Vehicle checkpoint configuration 2...

Page 4: ...thernet Appendix 4 p 2 and in browser address bar add the port number 49000 to controller IP address login password for initial entering admin admin After this Web server and system server are to be i...

Page 5: ...ces RS 485 Wiegand1 Number of reading devices via RS 485 interface up to 8 via Wiegand2 interface up to 8 Number of users min 50 000 Event memory capacity up to 150 000 Number of access cards for each...

Page 6: ...and on the item board IP address specified in the certificate and on the item board Subnet mask 255 0 0 0 gateway IP address 0 0 0 0 Following ways to set up IP address gateway and subnet mask are pro...

Page 7: ...board process execution module The XS1 XS2 terminal blocks of the upper board are connected to the XP1 XP2 connectors of the lower board The controller boards are shown in Fig 1 The terminal blocks ap...

Page 8: ...input IN 5 GND Common IN6 In 6 Additional input IN 6 XT2 RC1 connector FA FA Input for emergency unlocking passage opening Fire alarm GND Common DUA DUA 1 Control input of the OD1 from the RC button o...

Page 9: ...r upper board Following ways of IP address setting are possible see Table 2 1 User mode Jumper is removed If the user does not change the IP address gateway subnet mask the controller operates with de...

Page 10: ...t of a turnstile 2 o intrusion detectors of a vehicle checkpoint 2 o optional equipment IN 3 IN4 o door sensor 4 reed switch o PASS output of a turnstile 2 o optional equipment IN 4 IN5 IN6 o optional...

Page 11: ...N 10 DUSt button Stop on the RC panel 2 WRC 2 or optional equipment IN 11 DUB button B on the RC panel 2 WRC 2 or optional equipment IN 12 Activation and signals characteristics of the control element...

Page 12: ...notifications to central surveillance panel connection of other optional equipment Output signals characteristics Maximum commutation voltage of direct current max 30 V Maximum commutated current max...

Page 13: ...03 interface converter up to four readers with the Wiegand interface can be connected to the controller and when using four AC 02 1 converters up to 8 readers can be connected The connection layout a...

Page 14: ...Sect 7 1 Installation should be done in accordance with local building requirements 8 1 Cable lengths Cables for installation are shown in Table 3 Table 3 Cables used for installation N Equipment Cab...

Page 15: ...ning on the controller s board is presented in Fig 1 Installation of connected devices turnstiles locks power supply etc is performed according to the instructions given in technical documents of corr...

Page 16: ...n accordance with the Table 2 if necessary 6 Connect Ethernet cable to X2 connector of the controller upper board 7 Connect power source cable to XT4 terminal block of the controller lower board in ac...

Page 17: ...mechanical electromagnetic locks Sect 8 2 2 turnstile Sect 8 2 3 vehicle checkpoint Sect 8 2 4 RC panel WRC Sect 8 2 5 emergency unlocking devices Fire Alarm Sect 8 2 6 other optional equipment Sect 8...

Page 18: ...of the lock the latch to XT6 or XT9 terminal blocks on the lower board of the controller is performed in accordance with layout Fig 3 5 3 If connection of an Exit lock RC button is required connect it...

Page 19: ...Operation Manual 18 8 2 3 Turnstile and electromechanical gates configuration Figure 6 Connection layouts of Turnstile control configuration...

Page 20: ...iance with the layout Fig 6 3 Connect the turnstile the control unit of the turnstile to XT1 XT8 XT9 terminal blocks of the controller lower board in compliance with the layout Fig 6 4 Connect the swi...

Page 21: ...hicle checkpoint OD are given in Fig 8 Notes Output normalization parameter of OD should be set into After closing mode If operation is performed via one relay Automatic closing function should be tur...

Page 22: ...CT L 14 Controller 21 Figure 8 Connection layouts of boom barriers to the controller of vehicle checkpoint Figure 9 Connection layout of intrusion detectors...

Page 23: ...assage opening of all ODs connected to the controller board and the controllers of the second level except ODs which are in Security operating mode the possibility of emergency unlocking is to be conf...

Page 24: ...ional equipment with inductive load Rn to the outputs it is necessary to use spark protection diode VD1 in Fig 12 For example Schottky diode for operating current of min 1A 1N5819 Figure 11 Connection...

Page 25: ...n Turn on the power source the LED indication is to light up on the controller housing It means that the controller is switched on 2 Connect to the controller Web interface via Ethernet network Append...

Page 26: ...ler Web interface using computer via Ethernet Appendix 4 p 2 and in browser address bar add the port number 49000 to controller IP address login password for initial entering admin admin After this We...

Page 27: ...ly transferred to the database on security system server Availability of verification function depends on installed extensions of network software 11 1 ACS operating modes The change of operating mode...

Page 28: ...of the Fire Alarm input Any card 1 3 0 21 off off off No Open on off off off Control off on off off Security off 1 Hz 1 Hz off Closed off off on off Card is not authorized for access Open on off off 0...

Page 29: ...Network settings in the computer are missing set IP address and subnet mask of the computer The controller should be connected either directly to network connector of network card of the computer or t...

Page 30: ...aintenance and monitoring of the technical condition of means of the security fire alarm system Respecting of periodicity technological order and methods of execution of maintenance work are required...

Page 31: ...troller by simulating the actuation of detectors in accordance with the resources configuration Indication on the controller corresponding to events is on Formation of signals at the outputs according...

Page 32: ...CT L 14 Controller 31 APPENDICES Appendix 1 Instruction on connection of the card capture reader Figure 15 IC 05 card capture reader connection layout...

Page 33: ...nfiguring the controller and the IC05 card capture reader is described in the Administrator s Guide of these systems and also in the IC05 Operation Manual An example of connection of the PERCo card ca...

Page 34: ...nd of all the devices powered by it must not exceed 12 W It is also recommended to leave min 10 reserve power Splitter description PoE splitter hereinafter splitter is designed for energizing equipmen...

Page 35: ...roller for lock chamber management Lock chamber is intermediate detached space passage through an OD which excludes a possibility of a pass through without additional verification visual identificatio...

Page 36: ...egard to the lock chamber Reader can be replaced or duplicated by the RC button see below the lock chamber OD settings For comfort of use in the Web interface of the controller the lock chamber is pre...

Page 37: ...r OD settings To operate the lock chamber passageway control sensors are activated PASS A and PASS B of turnstile 1 for direction of the passages 1 and 2 through OD1 PASS A and PASS B of turnstile 2 f...

Page 38: ...3 5 Reading format of the card identifiers 40 4 CONFIGURATION 41 4 1 Controller configuration template 41 4 2 Configuration of the controller resources settings 42 4 2 1 Operating devices 42 4 2 2 Ph...

Page 39: ...2 3 Make sure that the computer and the controller are on the same subnet Ethernet It may become necessary to change network settings of the computer browser settings and to check operation of the net...

Page 40: ...g devices Physical contacts Readers Internal responses Events filters Access Time access criteria Time zones Holidays Weekly schedule Shift day Flexible weekly Users Operating device control Events St...

Page 41: ...Server in the Web interface menu The page with working area will be opened 2 In the opened window make the necessary changes for the parameters Server address parameter sets the server address Encrypt...

Page 42: ...be reset to the default template parameters The list of recorded access cards identifiers related user information access rights and parameters remain the same To change the configuration of the cont...

Page 43: ...ill be opened 3 In the opened window on the Device management Security General access Access by direction tabs make the necessary changes of the settings for corresponding resources 4 Click the Save b...

Page 44: ...e physical contact is attached to are to be set Inputs and outputs that are not involved in the template the value is Input Output These inputs and outputs are available for the task and changes in th...

Page 45: ...e deleted 4 2 3 Readers In all controller configurations to each direction of every OD one reader or one infrared panel hereafter reader is assigned If necessary it is possible to add into the configu...

Page 46: ...arameter sets line with Trassir server IP address Port parameter sets Trassir server port number Password parameter sets Trassir server authorization password Movement line parameter sets the number o...

Page 47: ...se launch Response time and Response characteristics parameters set corresponding response settings 4 Click the Save button The Internal response window will be closed the changed settings will be pas...

Page 48: ...l command Verification parameter sets the verification confirmation passage counter denial RC panel denial EVD denial Software denial verification timeout no response from passage counter no response...

Page 49: ...t the Cancel button Also it is possible to close the window by clicking Close 6 To delete the time zone from the list click the title bar in the working area the Time zones window will be opened Selec...

Page 50: ...from the list click the title bar in the working area the Holidays window will be opened Click the Delete button The Holidays window will be closed and the selected day will be deleted 5 1 3 Weekly sc...

Page 51: ...lick the Add button to change or delete the Flexible daily schedule parameters click the title bar in the working area The Flexible daily schedule window will be opened 3 In the opened window perform...

Page 52: ...r click the Save button The Flexible weekly schedule window will be closed 5 To exit the Flexible weekly schedule window without saving the changes select the Cancel button Also it is possible to clos...

Page 53: ...ilarly if needed 5 Using the Fingerprints tab assign to the user the fingerprints For this purpose Click the Activate complement button and place the finger on the reader device To delete all the fing...

Page 54: ...Note When arming the direction of the OD associated with the reader is set you select it in the dropdown Direction list When you unlock the OD will be unlocked for the time chosen in the drop down li...

Page 55: ...ut state change Functioning Service 5 Use the Range beginning point and Range end point fields to set the period of the report 6 Click the Apply button to apply the filter click the Cancel button to c...

Page 56: ...from Morpho click the Delete all fingerprints from Morpho button 4 To update the controller software firmware indicate the location of the software file using the Browse button and click the Download...

Page 57: ...PERCo Polytechnicheskaya str 4 block 2 194021 Saint Petersburg Russia Tel 7 812 247 04 64 E mail export perco com support perco com www perco com...

Page 58: ...www perco com...

Reviews: