Original manual in German Version 1.0.2 2022.10.06
13/39
7.3
Overview of the connection diagram
DANGER!
Risk of death due to high voltage.
All electrical work on the device may only be conducted by properly trained specialists under
compliance with the applicable safety regulations!
7.3.1
The power pack NT_SCHW-8
Fuse
Current
Function
F1
315 mA
Without function in this device series
F2
2 A
Primary fuse
F3
1 A
Without function in this device series
F4
4 A
230 VAC outlet relay K2 and K3
F5
1 A
Without function in this device series
Plug
Function
SL1
Power inlet 230 VAC
SL2
Relay - K1 – temperature 230 VAC
SL3
Relay - K2 - disinfection 230 VAC
SL4
Relay - K3 – pH regulation 230 VAC
The picture shows an example of the connection of two external 230 volt dosing pumps (dosing devices).