2
0
1
8
-0
9
8
Product Description
Front Panel
Figure 2.3
Front panel overview
Power:
The "Power" LED lights up green:
The WCS-CG310 interface module is correctly connected to the power supply.
State:
The "State" LED lights up green:
Data is being exchanged with the WCS reader. The four "Error No/Select ID" LEDs are used to
display the number of the currently polled WCS reader.
The "State" LED lights up red:
The interface module has detected a fault or a warning. The interface module displays the
binary coded error and/or warning number via the "Error No/Select ID" LEDs.
Error No/Select ID
Reader address
8
4
2
1
0
0
0
1
0
0
0
1
0
1
0
1
0
0
2
1
0
0
0
3
Error (No. 1...5):
Switch the interface module off and back on. If the error occurs
again, the module must be replaced.
Warning (No. 6...15):
These warnings are for information only, are displayed for 1
minute, and are then automatically reset. If these warnings occur
more frequently, notify customer service.
CANopen
Termination
Po
w
e
r/
Sta
te
B
u
s
P
o
w
e
r
1
2
4
8
S4
S5
Sta
te
B
u
s
Sta
te
B
a
u
d
o n
o f f
WCS-CG310 Modul
00 = 1 MBaud
01 = 500 KBaud
10 = 250 KBaud
11 = 125 KBaud
0
1
5 4 3 2 1 0
Node-ID
A
B
C
D0123
4
5
678
9
A
B
C
D0123
4
5
678
9