SmartRunner Matcher*
Installation
2
018-
01
17
Figure 3.3
Connection layout
Fuchs single-ended female cordsets are manufactured in accordance with EN60947-
5-2. When using a V19-G-5M-PUR-ABG single-ended female cordset with an open cable end,
connector pins are assigned as follows:
Pin
Wire color
Signal
Description
1
white
IN trigger
Trigger input. Triggers an evaluation, if the
sensor is in continuous evaluation mode
(independent)
2
brown
+UB
+ 24 V power supply
3
green
Data+ RS-485 RS-485 interface: Data +
4
yellow
Data- RS-485 RS-485 interface: Data -
5
gray
Teach
Control signal for teaching in the background
line
6
pink
Good
Output 1 is set if the height profile detected
matches the taught-in profile in terms of form
and position.
Once the teach-in process has been
performed, this output signals that teach-in
was successful
7
blue
GND
Ground for the + 24 V power supply
8
red
Bad
Output 2 is set if:
No object has been detected
or
The form detected does not match the
taught-in form
or
The position detected is outside the
tolerance.
Once the teach-in process has been
performed, this output signals that teach-in
has not been successful
1
4
6
7
8
5
3
2