2
018-
01
12
SmartRunner Matcher*
Product Specifications
2.5
Interfaces
The RS-485 Interface
The reader is equipped with an RS-485 interface for communication purposes, i.e.,
parameterizing the reader functions or reading out current process data during operation. This
interface is operated in 8-E-1 operating mode and fitted with a terminator that can be activated
or deactivated by parameterizing the sensor head.
The RS-485 interface supports the following transfer rates:
38400 bit/s
57600 bit/s
76800 bit/s
115200 bit/s
(default value)
230400 bit/s
Data structure of the RS-485 interface
3
Result (green/red)
Lights up green if a scanned profile matches a taught-
in profile
Lights up red if a scanned profile does not match a
taught-in profile
Applies in Code Card
mode
Lights up green when a correct code has been read
Lights up red when an incorrect code has been read
Off if no code has been read
4
Match 1/2
(green/yellow)
Lights up green if the scanned profile matches the
taught-in profile 1 (MATCH 1)
Lights up yellow if the scanned profile matches the
taught-in profile 2 (MATCH 2), optional
5
Diagnosis (red)
Lights up red if a bus error has occurred
Lights up red if a system error has occurred on the
interface controller
Flashes red if the sensor is in Update mode
6
POWER (green)
Lights up as soon as voltage is present
Flashes in Configuration mode
7
Teach in (yellow)
Lights up yellow during the teach in process
8
TRIGGER (yellow)
Lights up yellow if the hardware trigger signal is
activated
Position
Designation
Function