![Pepperl+Fuchs PXV F200-B25-V1D Series Manual Download Page 21](http://html.mh-extra.com/html/pepperl-fuchs/pxv-f200-b25-v1d-series/pxv-f200-b25-v1d-series_manual_1528046021.webp)
Commissioning
2
0
1
5
-0
9
21
The
Vision Configurator
is a useful and easy-to-use piece of software for configuring the read
The PC connection required for programming and the read head power supply can be made
using a special parameterization cable. This parameterization cable can be ordered as an
accessory under the name "Cable unit for service interface with the power supply". This also
provides the electrical supply to the read head. The parameterization cable is connected to the
read head using the "Main" connector.
Connection of the Parameterization Cable
1. First connect the round plug connector to the read head.
2. Connect the plug-in power supply to the parameterization cable.
3. Plug the plug-in power supply into a socket.
The ring light of the read head and the "PWR/ADJ/ERR/NO CODE" LED2 lights up or
flashes.
4. You can now connect the USB plug-in connector to your PC.
Parameterizing the read head
1. Start the
Vision Configurator
software on the PC.
2. Program the read head with the help of the "Vision Configurator" manual.
3. Transfer the parameter list to the read head.
4. Save the parameterization.
5. Unplug the plug-in power supply from the wall outlet to turn off the power supply at the head.
6. Remove the parameterization cable's USB plug-in connector from your PC
7. Remove the configuration cable from the read head.
The read head is now parameterized according to your specifications and can be used in
your application.
6.2.2
External Parameterization Using Code Cards
During external parameterization, the read head scans special code cards optically and
configures the relevant parameters. Simply hold the corresponding code cards at the correct
distance in front of the lens on the PCV...-F200- read head. The standard code cards are
contained in the appendix.
The following parameters can be configured using code cards:
■
Read head resolution [0.1 mm, 1 mm, 10 mm]
■
Read head orientation [0
°
; 180
°
; 0
°
or 180
°
, 0
°
, 90
°
, 180
°
or 270
°
]
■
Function of output 1 [none, speed exceeded, warning, fault, contamination, event, no
position]
■
Function of output 2 [none, speed exceeded, warning, fault, contamination, event, no
position]
■
Function of output 3 [none, speed exceeded, warning, fault, contamination, event, no
position]