Installation
2
0
1
5
-0
9
19
5.4
EtherNet/IP Connection
The PCV... read head is connected to EtherNet/IP via two 4-pin, D-coded device sockets, M12
x 1,
EtherNet/IP 1
and
EtherNet/IP 2
, on the side of the housing.
Figure 5.9
Figure 5.10
For suitable Ethernet cables, see see chapter 4.5.
Caution!
Damage to the device
Connecting an alternating current or excessive supply voltage can damage the device or cause
the device to malfunction.
Electrical connections with reversed polarity can damage the device or cause the device to
malfunction.
Connect the device to direct current (DC). Ensure that the supply voltage rating is within the
specified device range. Ensure that the connecting wires on the female cordset are connected
correctly.
Connector Occupancy
1
2
3
4
TX +
RX +
TX -
RX -
B
u
s
EtherNet/IP 1 & 2
1
3
4
2