background image

Manual

PSU-IDM160-BD-1D-J1-*-N0

PSU-IDM260-D-2D-J1-*-S-N0

Power module

Summary of Contents for PSU-IDM160-BD-1D-J1-N0 Series

Page 1: ...Manual PSU IDM160 BD 1D J1 N0 PSU IDM260 D 2D J1 S N0 Power module...

Page 2: ......

Page 3: ...ms of Supply for Products and Services in the Electronics Industry set out by the German Electrical and Electronic Manufacturers Association ZVEI and the Extended Reservation of Proprietorship supplem...

Page 4: ...eld Readers 12 2 4 Use 13 3 System Structure 14 4 Commissioning 15 4 1 Installation 15 4 2 Pin assignment in the terminal compartment PSU IDM160 BD 1D J1 DC S N0 and PSU IDM260 D 2D J1 DC S N0 17 4 5...

Page 5: ......

Page 6: ...ding to the risk level as follows Danger This symbol warns you of an immediate and present danger If you do not observe this warning message there is a risk of personal injury and even death WARNING T...

Page 7: ...s If you do not observe this information the intended use in explosion haz ardous areas cannot be guaranteed Observe the information given in this manual during commissioning and use of the product Th...

Page 8: ...tion laws e g Ordinance on Industrial Safety and Health BetrSichV Do not open the device You may not make any changes to the device You may not exchange or replace any components Explosion protection...

Page 9: ...ns and proper operation are observed Inspection The operator must appoint an electrician to check an electrically powered device in explosion hazardous areas to ensure it is in correct condition IEC 6...

Page 10: ...J1 DC S N0 PSU IDM160 BD 1D J1 DC U N0 PSU IDM160 BD 1D J1 AC S N0 PSU IDM160 BD 1D J1 AC U N0 Description Power supply for the intrinsically safe supply of wired 1 D barcode readers IDM160 D 1D J1 an...

Page 11: ...C Relative humidity 95 non condensing Housing material Aluminum Mechanical Data Degree of pro tection IP64 Dimensions W x H x D 140 mm x 250 mm x 56 mm Weight approx 3 1 kg 2 3 Technical Data Power Mo...

Page 12: ...emperature 25 C to 60 C Storage temperature 40 C to 60 C Relative humidity 95 non condensing Mechanical Data Housing material Aluminum Degree of pro tection IP64 Dimensions W x H x D 140 mm x 250 mm x...

Page 13: ...60 D 1D J1 IDM260 D 2D J1 as well as to Blue tooth base station IDMx61 B J1 BT N0 and charging cradle IDMx61 C BT N0 The corresponding system configurations of the power module with the respective han...

Page 14: ...e a diameter of 7 mm Figure 1 Mounting points for installation 2 The connections for equipotential bonding M5 x 10 are located on both the front and back of the power module 2 Figure 2 Equipotential b...

Page 15: ...tion in explosion hazardous areas it must be ensured that the housing is completely closed again and screwed on properly Note Changes to the wiring may only be carried out by trained and qualified per...

Page 16: ...inal blocks in the terminal compartment Assignment for Ex e terminal compartment Terminal no Designation Description X1 L 24 V DC X2 N 0 V DC X3 PE Protective earth X4 GND RS232 X5 TxD RS232 X6 Shield...

Page 17: ...blocks in the terminal compartment Assignment for Ex e terminal compartment Terminal no Designation Description X1 L 24 V DC X2 N 0 V DC X3 PE Protective earth X4 GND USB X5 Shield USB X6 n c X7 D USB...

Page 18: ...s in the terminal compartment Assignment for Ex e terminal compartment Terminal no Designation Description X1 L L 100 250 V DC X2 N N Neutral conductor X3 PE Protective earth X4 GND RS232 X5 TxD RS232...

Page 19: ...the terminal compartment Assignment for Ex e terminal compartment Terminal no Designation Description X1 L L 100 250 V DC X2 N N Neutral conductor X3 PE Protective earth X4 GND USB X5 Shield USB X6 n...

Page 20: ...handheld scanner IDMx61 B N0 BT N0 Bluetooth base station charging cradle No explosion protection For IDMx61 Bluetooth handheld scanner IDMx61 C N0 BT N0 Charging cradle No explosion protection For ID...

Page 21: ...spiral For IDMx60 D CBL IDM160 D J1 U S18 N0 RS232 connection cable wired 1 D handheld scanner ATEX IECEx Zone 1 21 1 8 m length smooth For IDM160 D CBL IDM160 D J1 U C38 N0 RS232 connection cable wi...

Page 22: ...h AG XX00 surrounding enclosure HOLDER BRACKET XX00 IDMx61 B N0 Stainless steel bracket for mounting the base station IDMx61 B J1 BT N0 to the AG XX00 surrounding enclosure BAT IDMx61 M Replacement ba...

Page 23: ...00 00 00 www pepperl fuchs com Subject to modifications Pepperl Fuchs Printed in Germany Part No 000000 00 00 00 Pepperl Fuchs Quality Download our latest policy here www pepperl fuchs com quality www...

Reviews: