Installation
2
0
1
9
-0
2
13
5.3
Preparation
Unpacking the device
1. Check the packaging and contents for damage.
In the event of damage, inform the shipping company and notify the supplier.
2. Check the package contents against your order and the shipping documents for
completeness and accuracy.
Should you have any questions, direct them to Fuchs.
3. Retain the original packaging in case the device is to be stored or shipped again at a later
date.
5.4
Mounting
■
A flush mount is possible in metallic and nonmetallic environments.
■
The distance between the measuring field (framed area at the front of the sensor) and the
mounting base or fastening screws on the damping element must be at least 3 mm.
Watch out for any protruding metal parts such as screw heads when mounting the device.
■
The damping element must be attached to the sensor at a right angle to guarantee the
relevant measurement accuracy.
■
The distance between the damping element and the sensor can be a maximum of 2.5 mm
and must be at least 1 mm.
Distance of the Damping Element
5.5
Connection
Connecting the supply voltage
To supply voltage to the sensor, proceed as follows:
1. Insert the prepared connection cable into the connector plug provided for this purpose on the
underside of the housing.
2. Screw the cap nut onto the connector plug as far as it will go. This ensures that the power
cable cannot be inadvertently pulled out.
3. Now connect the supply voltage to the cable provided.
The sensor is now ready for operation.
< 2.5 mm
> 10
mm