![Pepperl+Fuchs PCV F200-B17-V1D Series Manual Download Page 30](http://html.mh-extra.com/html/pepperl-fuchs/pcv-f200-b17-v1d-series/pcv-f200-b17-v1d-series_manual_1528038030.webp)
2
0
2
0
-1
1
30
Operation and communication
7.1.5.2
Global Primary Data
The global primary data allows you to parameterize the read head using PROFINET. The global
primary data is always transferred to the read head in full.
Designation
Function
Parameter data Primary data
Orientation
Orientation of read head in relation to
code tape
Orientation
0
°
0/180
°
180
°
Code Tape Type
Configuration of code tape width
Code tape width
1 row
2 rows
3 rows
4 rows
5 rows
6 rows
7 rows
8 rows
X-Resolution
Multiplier for the length in the
direction of the X coordinate
Resolution
0.1 mm
1 mm
10 mm
Y-Resolution
Multiplier for the length in the
direction of the Y coordinate
Resolution
0.1 mm
1 mm
10 mm
Speed-
Resolution
Multiplier for the velocity output
Resolution
0.1 m/s
0.01 m/s
0.001 m/s
Horizontal Offset Offset in the direction of the
X coordinate
Length
0 mm
–
±
10,000,000 mm
Input Function
Function at input signal
Function of input
No Function
Output1 Function Meaning of the output signal at
output 1
Function of
output
No Function
Overspeed
Warning
Error
Event
No Position
Repair Strip
Output2 Function Meaning of the output signal at
output 2
Function of
output
No Function
Overspeed
Warning
Error
Event
No Position
Repair Strip
Output3 Function Meaning of the output signal at
output 3
Function of
output
No Function
Overspeed
Warning
Error
Event
No Position
Repair Strip
Output1
Overspeed Value
Speed at which output 1 is activated Speed
0 mm/s
–
65,534 mm/s
12,500 mm/s
Output2
Overspeed Value
Speed at which output 2 is activated Speed
0 mm/s
–
65,534 mm/s
12,500 mm/s
Output3
Overspeed Value
Speed at which output 3 is activated Speed
0 mm/s
–
65,534 mm/s
12,500 mm/s