Installation
2
0
1
5
-0
9
13
Figure 5.2
Position the code reel so that the
www.pepperl-fuchs.com
label and the position markings
are below the data matrix code. The position values then increase along the X-direction. The
diagram shows the orientation of a read head in the default position of 0
°
. The read head can
be configured in the interface for other installation situations.
Code Reels with a Starting Position of 0 m
Code Reels with Different Starting Positions
Orientation of the Code Reel and Read Head
Model Number
Description
PCV6M-CA20-0
Code reel, 2-track, length: 6 m
...
...
PCV100M-CA20-0
Code reel, 2-track, length: 100 m
Model Number
Description
PCV100M-CA20-0
Code reel, 2-track, length: 100 m, starting
position: 0 m
PCV100M-CA20-10000
Code reel, 2-track, length: 100 m, starting
position: 100 m
...
...
PCV100M-CA20-990000
Code reel, 2-track, length: 100 m, starting
position: 9,900 m
Y
Z
X
Caution!
Stop Edges
If you attach another code reel at the end of a previous code reel, the code pattern of 10 mm
must be retained.
Note!
Expansion Joints
If the system covers longer distances, expansion joints are integrated in the system structure.
We recommend creating breaks along the code reel. The resulting gaps should be 20 mm (2