IUH-F117-V1-*
Operation
20
13
-0
4
41
Memory Module for Tag Accesses to the "Memory Bank" MB
This parameter specifies the bank accessed by the read/write commands SR,
ER, SW, and EW.
Example:
WP1UMB.00.01.03 sets the bank to User Memory
7.6
Error/Status Messages
ParamTyp:
MB
Default:
MB = .03 = User Memory
Value range:
.00 = reserved (password area)
.01 = UII/EPC
.02 = TID
.03 = User Memory
Status
Meaning
0
The command was executed correctly.
1
Reserved
2
Switch-on message, reset was executed.
3
Reserved
4
The command is incorrect or incomplete.
The parameter is not in the valid area.
5
No read/write tag in the measurement range.
6
Hardware error, e.g., error during self-test or read/write head defective.
7
Internal device error.
8
Reserved
9
The parameterized tag type is not compatible with the connected read head.
A
There are several tags in the measurement range (IUH*).
B
Reserved
C
Reserved
D
Reserved
E
Internal buffer overflow; execute reset.
F
Reserved