Commissioning
20
13
-0
3
23
6.2
Connection
When the supply voltage is connected and the device is initialized, the PWR/ERR
LED lights up green. If the LED lights up red, either the initialization process has
not yet finished or there is a device fault.
6.3
Device settings
You must set the various parameters prior to commissioning.
The parameters are volatile and non-volatile parameters. Volatile parameters are
reset to their default setting when the system is switched off and on again.
Non-volatile parameters
Volatile parameters
Configure the read/write head with the described system commands ().
“
99
”
is
preset as the data carrier type.
Warning!
Incorrect electrical connection
Incorrect connections may damage the system.
Before commissioning, familiarize yourself with the system of communication
between your PROFIBUS DP and the read/write station. Check all connections
before commissioning.
Warning!
Device not configured or configured incorrectly
Configure the device prior to commissioning. A device that has not been
configured or configured incorrectly may lead to faults in the plant.
Parameter
Default setting
Value range
R/W head
Data carrier type
99
00 ... FF
PROFIBUS interface
Slave address
7E
00 ... 7E
Parameter
Default setting
Value range
R/W head
Password mode
Off
on / off
Password
00000000
00000000 ... FFFFFFFF