VB24
79
6.4
RS232 MASTER/SLAVE
NOTE
This interface is provided for backward compatibility. We recommend using
the more efficient ID-NET™ network for Master/Slave or Multiplexer layouts.
The RS232 master/slave connection is used to collect data from several scanners to build either
a multi-point or a multi-sided reading system; there can be one master and up to 9 slaves
connected together.
The Slave scanners use RS232 only on the main and auxiliary serial interfaces. Each slave
VB24 transmits the messages received by the auxiliary interface onto the main interface. All
messages will be passed through this chain to the Master.
The Master scanner is connected to the Host on the RS232/RS485 main serial interface.
There is a single reading phase and a single message from the master scanner to the Host
computer.
Either On-Line or Serial On-Line Operating modes can be used in this layout.
When On-Line Operating mode is used, the external trigger signal is unique to the
system, however it is not necessary to bring the external trigger signal to the Slave
scanners.
The main and auxiliary ports are connected as shown in the figure below.
3
Figure 75 – RS232 Master/Slave Layout
Host
1
2
1
Master
Main Serial Interface (RS232 only)
Auxiliary Serial Interface (RS232)
External Trigger (for On-Line Mode)
2
1
Slave#1
Slave#n
Power
Summary of Contents for FUQ-B8
Page 1: ...VB24 BARCODE SCANNER FABRIKAUTOMATION MANUAL ...
Page 22: ...VB24 12 b Operating mode selection and definition c Digital Outputs configuration ...
Page 55: ...VB24 45 Figure 29 ID NET Network Connections with Common Power Branch Network ...
Page 56: ...VB24 46 Figure 30 ID NET Network Connections with Common Power Star Network ...
Page 73: ...VB24 63 Figure 53 ID NET Network Connections with Common Power Branch Network ...
Page 74: ...VB24 64 Figure 54 ID NET Network Connections with Common Power Star Network ...
Page 112: ...VB24 102 T Technical Features 108 Troubleshooting 105 Typical Layouts 77 ...