background image

LS682-DA

Safety

 2

0

1

5

-0

5

7

3

Safety

3.1

Symbols Relevant to Safety

3.2

Intended Use

The optical data coupler serves as an optical link between two Ethernet devices; 
typically one is mobile.

Always operate the device as described in these instructions to ensure that the 
device and connected systems function correctly. The protection of operating 
personnel and plant is only guaranteed if the device is operated in accordance 
with its intended use.

Only use recommended original accessories.

The operating company bears responsibility for observing locally applicable 
safety regulations.

Installation and commissioning of all devices must be performed by a trained 
professional only.

User modification and or repair are dangerous and will void the warranty and 
exclude the manufacturer from any liability. If serious faults occur, stop using the 
device. Secure the device against inadvertent operation. In the event of repairs, 
return the device to your local Fuchs representative or sales office. 

Compatibility with the LS680 Optical Data Coupler

The LS680 and LS682 optical data couplers operate according to the same 
functional principle. Due to technical modifications, mixed operation of both 
device models is not possible. In mixed operation, the alignment LED shows a 
receiving level; however, valid Ethernet data cannot be received.

Danger!

This symbol indicates an imminent danger.

Non-observance will result in personal injury or death.

Warning!

This symbol indicates a possible fault or danger.

Non-observance may cause personal injury or serious property damage.

Caution!

This symbol indicates a possible fault.

Non-observance could interrupt the device and any connected systems and 
plants, or result in their complete failure.

Summary of Contents for 260312

Page 1: ...R LS682 DA Optical Data Coupler FACTORY AUTOMATION MANUAL...

Page 2: ...Terms of Delivery for Products and Services of the Electrical Industry published by the Central Association of the Electrical Industry Zentralverband Elektrotechnik und Elektroindustrie ZVEI e V in i...

Page 3: ...very 13 4 6 Accessories 13 4 6 1 Mounting Accessories 13 4 6 2 Connecting Cables 13 4 6 3 Network Connecting Cable 14 5 Installation 15 5 1 Preparation 15 5 2 Mounting 15 5 3 Connection 16 5 4 Storage...

Page 4: ...ize the device s entire range of functions reduce faulty operation and the associated errors reduce costs from downtime and incidental repairs increase the effectiveness and operating efficiency of yo...

Page 5: ...tion on your product at http www pepperl fuchs com Simply enter the product name or model number in the Product Key word search box and click Search Select your product from the list of search results...

Page 6: ...ed and manufactured under observance of the applicable European standards and guidelines The product manufacturer Pepperl Fuchs GmbH D 68307 Mannheim has a certified quality assurance system that conf...

Page 7: ...e the manufacturer from any liability If serious faults occur stop using the device Secure the device against inadvertent operation In the event of repairs return the device to your local Pepperl Fuch...

Page 8: ...ried out by authorized service personnel LASER LIGHT DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS LASER 1M LASER PRODUCT IEC 60825 1 2007 CERTIFIED COMPLIES WITH 21 CFR 1040 10 AND 1040 11 EXCEPT FOR...

Page 9: ...CTLY WITH OPTICAL INSTRUMENTS LASER 1M LASER PRODUCT IEC 60825 1 2007 CERTIFIED COMPLIES WITH 21 CFR 1040 10 AND 1040 11 EXCEPT FOR DEVIA TIONS PURSUANT TO LASER NOTICE NO 50 DATED JUNE 24 2007 RAYONN...

Page 10: ...ed using switches that have been certified for use with the bus system in question All layer 2 telegrams IEEE 802 3 Clause 25 are physically transported There is no saving of telegrams so the transfer...

Page 11: ...on with increased detection range of 300 m for deep freeze applications frequency 1 265355 LS682 DA EN F2 35 146 Version with increased detection range of 300 m for deep freeze applications frequency...

Page 12: ...D flashes when the optical connection is stabilized through correct alignment SIGNAL The optical signal strength is displayed as an alignment aid during adjustment of the optical data couplers Additio...

Page 13: ...re available for selection 1 Transmit Data 2 Receive Data 3 Transmit Data 4 Receive Data 1 3 4 2 Designation Description OMH LS610 01 Adjustment unit OMH LS610 02 Direct mounting set 4 M4 threaded ins...

Page 14: ...V1 W 2M PVC Female single ended cordset angled M12 4 pin PVC cable length 2 m V1 W 2M PUR Female single ended cordset angled M12 4 pin PUR cable length 2 m V1 W 5M PVC Female single ended cordset angl...

Page 15: ...ship the unit at a later time 5 2 Mounting The device has two mounting holes as well as four retaining feet for easy installation M4 inserts can also be pressed into these four feet This allows existi...

Page 16: ...the power has to be supplied as a low protective voltage PELV and limited according to UL Class 2 100 W The optical data coupler is supplied with a direct voltage of 18 VDC 30 VDC The insulation test...

Page 17: ...the socket pro vided on the rear of the housing 2 Screw the cap nut onto the connector as far as it will go This ensures that the power cable cannot be inadvertently pulled out 3 Now connect the netwo...

Page 18: ...a receiver detects the emitted light of the device opposite it the flashing frequency of the alignment LED decreases When the alignment LED goes out the devices are optimally aligned Sufficient exces...

Page 19: ...when aligning can be read directly on the device It is no longer necessary to have someone helping on the opposite side The bidirectional display mode starts automatically when the LS682 optical data...

Page 20: ...is greater than the reception level of the local device green LED lights up local device green LED flashes opposite side Figure 6 6 The reception level of the opposite side is unknown interruption of...

Page 21: ...aid Connect the power supply 3 Roughly align the device at a distance of around 3 5 m until both signal indicators lie in the green zone Ensure that the optical data couplers are at the same height an...

Page 22: ...ents tighten the central M6 screw to fix the position in the horizontal direction Parallel light paths If two light paths are installed next to each other without any optical separation the optical da...

Page 23: ...nformation must always be controlled by an external switch The internal Ethernet adapter is permanently set to 100 MBit full duplex as this is the only format that is converted for the optical transmi...

Page 24: ...the device in water Do not spray the device with water or other fluids Do not use a scouring agent to clean the surface of the device Use a cotton or paper cloth moistened with water or isopropyl alco...

Page 25: ...a wiring fault in the distributor or switch cabinet Check whether there is a reason why the power supply is switched off installation or maintenance work etc Switch on the power supply if appropriate...

Page 26: ...G OPTICAL INSTRUMENTS VISIBLE LASER BEAM DO NOT LOOK DIRECTLY AT THE LASER BEAM USING OPTICAL INSTRUMENTS Laser class 1M Wavelength 785 nm 660 nm Beam divergence 15 mrad Pulse duration 8 ns Repeat rat...

Page 27: ...0 BASE TX LS682 DA EN F1 LS682 DA EN F2 Pre fault output 1 PNP inactive when below the signal strength short circuit proof max 200 mA LS682 DA EN F1 LS682 DA EN F2 Ambient temperature 10 C 50 C 14 F 1...

Page 28: ...5 LS682 DA EN F2 35 Effective operating distance 0 m 300 m Range limit 350 m Light source Laser diode Light type Modulated infrared light Modulated red light Laser nominal ratings Note INVISIBLE LASER...

Page 29: ...link Red LED ERROR Function indicator Signal strength 8 LEDs red yellow green LS682 DA EN F1 35 LS682 DA EN F2 35 Operating voltage 18 VDC 30 VDC No load current 200 mA Data rate 100 MBit s Fast Ethe...

Page 30: ...g 4 pin standard power supply M12x1 plug 8 pin service M12x1 socket 4 pin D coded LAN Material Housing ABS PC Optical face Plastic Weight 700 g LS682 DA EN F1 35 LS682 DA EN F2 35 Directive conformity...

Page 31: ...L INSTRUMENTS VISIBLE LASER BEAM DO NOT LOOK DIRECTLY AT THE LASER BEAM USING OPTICAL INSTRUMENTS Laser class 1M Wavelength 785 nm 660 nm Beam divergence 15 mrad Pulse duration 8 ns Repeat rate 62 5 M...

Page 32: ...E TX LS682 DA EN F1 146 LS682 DA EN F2 146 Pre fault output 1 PNP inactive when below the signal strength short circuit proof max 200 mA LS682 DA EN F1 146 LS682 DA EN F2 146 Ambient temperature 30 C...

Page 33: ...N F1 35 146 LS682 DA EN F2 35 146 Effective operating distance 0 m 300 m Range limit 350 m Light source Laser diode Light type Modulated infrared light Modulated red light Laser nominal ratings Note I...

Page 34: ...35 146 LS682 DA EN F2 35 146 Operating voltage 18 VDC 30 VDC No load current 200 mA Data rate 100 MBit s Fast Ethernet LS682 DA EN F1 35 146 LS682 DA EN F2 35 146 Interface type 100 BASE TX LS682 DA...

Page 35: ...BS PC Optical face Plastic Weight 700 g LS682 DA EN F1 35 146 LS682 DA EN F2 35 146 Directive conformity EMC Directive 2004 108 EC EN 61000 6 2 2005 EN 60947 5 2 2007 Conformity with standards Laser c...

Page 36: ...hs GmbH 68307 Mannheim Germany Tel 49 621 776 0 E mail info de pepperl fuchs com USA Headquarters Pepperl Fuchs Inc Twinsburg Ohio 44087 USA Tel 1 330 4253555 E mail sales us pepperl fuchs com Asia Pa...