Pentair NOCCHI CPS 10 Manual Download Page 1

IT     -     ISTRUZIONI ORIGINALI IN LINGUA ITALIANA

IT   PAGE 1 EN  PAGE 21

ES  PAGE   81

FR   PAGE   41

NL  PAGE 101 RUS  PAGE 121

DE  PAGE   61

CPS 10 

CPS 20

PL PAGE 143

Distributed in NZ By:

Freephone 0508 634 34

  1

7 Monier Pl, Mt Wellington, Auckland 1060, New 
Zealand

Summary of Contents for NOCCHI CPS 10

Page 1: ...I IN LINGUA ITALIANA IT PAGE 1 EN PAGE 21 ES PAGE 81 FR PAGE 41 NL PAGE 101 RUS PAGE 121 DE PAGE 61 CPS 10 CPS 20 PL PAGE 143 Distributed in NZ By Freephone 0508 634 341 7 Monier Pl Mt Wellington Auck...

Page 2: ...OL PANEL DESCRIPTION 28 5 2 DESCRIPTION OF SIGNALS ON DISPLAY 28 5 3 PROGRAMMING MENU 29 5 3 1 PROGRAMMING CLOCK DAY 30 5 3 2 SET POINT 30 5 3 3 ADVANCED PARAMETERS 31 5 3 4 INSTALLATION PARAMETERS 32...

Page 3: ...liquids Incorrect use can dangerously damage the machine or the equipment as well as result in guarantee forfeiture WARNING ATTENTION ATTENTION ATTENTION ATTENTION 1 1 PARTICULAR SIGNS 1 2 GENERAL INF...

Page 4: ...se specific guards and equipment as per safety standards Fully comply with safety and accident prevention standards in force This appliance is not intended for use by persons including children with r...

Page 5: ...essure of the first tank on the system this value must be 0 5 0 8 Bar less than working pressure lower SET POINT For connection to the aqueduct pay full attention to local standards in force Perform t...

Page 6: ...ing see chapter 5 Follow the instructions below to connect the machine to the electrical power supply system Perform the electrical connections in compliance with local standards in force The installe...

Page 7: ...e pressure to be maintained constant in the system reducing or increasing the rotation speed of the pump motor When the system pressure goes below the threshold set the module starts the pump to reset...

Page 8: ...tops because of a fault the second pump will automatically substitute it The second pump cannot support the first in this mode ALTERNATING WITH RUNNING HOURS The two motors function based on the numbe...

Page 9: ...quency graph indicator Frequency graph indicator Day of the week Master P or Slave S only for unit configuration Day of the week GB The control panel is shown in picture below Indication Day Hour Pres...

Page 10: ...arm for a description of alarm codes please see Chpt 6 0 For a correct configuration we recommend using the installation and advanced parameters with the machine on STOP and connected to the power sup...

Page 11: ...e buttons it is possible to modify the time Press MODE to move onto changing the day With the buttons it is possible to modify the day To save the values press SET The symbol will disappear and the wo...

Page 12: ...E Unit of measurement Pressure unit of measurement BAR BAR PSI SET N Number of SET POINTS Number of set points used 1 1 2 ROT Motor rotation direction Motor rotation direction POS POS NEG COR Nominal...

Page 13: ...for water will be the one which has run for the least amount of time see functioning hours parameter The second pump cannot support the first in this mode CH05 In this setting the first pump to start...

Page 14: ...or lack of water seconds 15 5 300 ORE P Hours running Number of hours the pump has been running N A N A N A SCA T Exchange time Parameter indicating the amount of time a pump must run for Once this va...

Page 15: ...nal command which closes entry to the inhibitors NO NC Check the external inhibitor command i e switch float pressure gauge RPC Reset configuration REC Saving parameter signal RST Total reset signal T...

Page 16: ...tes and will repeat this procedure up to five times Press the START STOP button to attempt to exit these conditions Please contact technical support of the error persists E03 Definitive external error...

Page 17: ...ch restart the system E13 Configuration error This error occurs when the control board cannot correctly communicate with the power part This alarm condition closes the J3 contact on the power board fo...

Page 18: ...ESC ARROW DOWN ESC press for 10 seconds Press SET to confirm reset 7 3 SOFTWARE VERSION Key sequence to see the software version ARROW UP for 5 seconds 1 Type of motor pump 2 Maximum flow rate l min 3...

Page 19: ...HE NEGATIVE SUCTION HEAD 1 Basin or tank 2 Float 3 Shut off valve 4 Outlet tubing 5 Tank autoclave membrane 8 l min 6 Gauge 7 Pressure transducer 8 Flexible tube 9 Non return valve 10 Filter 11 Motor...

Page 20: ...he correct inclination of the suction piping until the air present in the tubing can exit the outlet tubing 1 Basin or tank 2 Float 3 Shut off valve 4 Outlet tubing 5 Tank autoclave membrane 8 l min 6...

Page 21: ...RD LINE Power entry J3 Alarm exit U1 V1 W1 Motor connections GB RS 485 Communication port INI INIBIT input NC external contact S P External Set Point EST NA contact NTC NTC sensor input to control tem...