Pentair MYERS MSP50 Owner'S Manual Download Page 1

NOTE! To the installer: Please make sure you provide 

this manual to the owner of the pumping equip ment or 

to the responsible party who maintains the system.

OWNER’S MANUAL

Submersible Sewage Ejector Pumps

© 2016 Pentair plc. All Rights Reserved. 

23833A705 (05/23/16)

293 WRIGHT STREET, DELAVAN, WI 53115  WWW.FEMYERS.COM
PH: 888-987-8677  ORDERS FAX: 800-426-9446

Summary of Contents for MYERS MSP50

Page 1: ...of the pumping equip ment or to the responsible party who maintains the system OWNER S MANUAL Submersible Sewage Ejector Pumps 2016 Pentair plc All Rights Reserved 23833A705 05 23 16 293 WRIGHT STREE...

Page 2: ...FPA 70 2001 Failure to heed above cautions could result in injury or death General Information Pump Warning NOTE Some city regulations do not allow installing a pump with plastic pipe Check local regu...

Page 3: ...3 Pump Installation...

Page 4: ...e plug 12 from top of housing and pour oil in container preferably glass so that oil can be observed If oil is clear it will indicate motor is not burned and there has been no water leaking into the m...

Page 5: ...sure it is not chipped Inspect seal after shaft is in place If seal has been chipped it must be replaced Do not replace rotating part of seal until the balance of the pump is assembled 7 Bearings Whe...

Page 6: ...y for check run before air testing and filling with oil Plug cord 21 into power receptacle and push up on switch chamber diaphragm 23 to start motor Motor should start and run smoothly When pressure i...

Page 7: ...d Nut 1 22 14623 010 1 Power Cord 10 1 22 14623 020 1 Power Cord 20 1 23 139 014 1 Ring Seal 1 1 11584 043 4 Nameplate 1 2 14981 001 1 Plug Pipe 1 4 1 3 56 023 2 Motor Housing Includes Handle 1 4 1359...

Page 8: ...ge Discharge 1 8 324 001 1 Gasket Discharge Flange 1 9 202 010 2 Volute 1 10 203 010 2 Bottom Plate 1 11 614 010 2 Impeller Automatic Manual 1 12 19109A070 Jam Nut 1 13 83 007 1 Seal Shaft 1 14 83 002...

Page 9: ...____________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________...

Page 10: ...____________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________...

Page 11: ...____________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________...

Page 12: ...or with single phase power through a phase converter will void the warranty Note also that three phase motors must be protected by three leg ambient compensated extra quick trip overload relays of the...