Pentair ICHNDHLD Installation Manual Download Page 1

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS

SAVE THESE INSTRUCTIONS

INTELLICENTER

 

 WIRELESS CONTROL SYSTEM

WIRELESS CONTROL PANEL

 

INSTALLATION  GUIDE

Summary of Contents for ICHNDHLD

Page 1: ...IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS INTELLICENTER WIRELESS CONTROL SYSTEM WIRELESS CONTROL PANEL INSTALLATION GUIDE ...

Page 2: ...ation 4 IntelliCenter Control System Wireless Controller kit 4 Mounting the Wireless Transceiver 4 Connecting the Transceiver to the IntelliCenter Control System Load Center 6 Home Screen 6 Transceiver Connected to the IntelliCenter Control System Load Center 8 IntelliCenter Control System Setup 9 Power On the Load Center 9 Setup the Wireless Control Panel 9 Wireless Control Panel Firmware Update ...

Page 3: ...applications only Most states and local codes regulate the construction installation and operation of public pools and spas and the construction of residential pools and spas It is important to comply with these codes many of which directly regulate the installation and use of this product Consult your local building and health codes for more informa tion This guide provides installation and opera...

Page 4: ...ONLY Failure to do so may cause property damage or personal injury For units intended for use in other than single family dwellings a clearly labeled emergency switch shall be provided as part of the installation The switch shall be readily accessible to the occupants and shall be installed at least five 5 feet 1 52 m away adjacent to and within sight of the unit Except for listed spa side remote ...

Page 5: ...is device may not cause interference and 2 This device must accept interference that may cause undesired operation of the device Le dispositif est conforme à la licence d Industrie Canada Exempt CNR Le fonctionnement est soumis à la suivante 1 Ce ne doit pas provoquer d interférences et 2 Cet appareil doit accepter les interférences qui peuvent causer un mauvais fonctionnement de l appareil This C...

Page 6: ... connected to the grounding means provided in the electric supply service panel with a continuous copper wire equivalent in size to the circuit conductors supplying this equipment no smaller than 12 AWG or 3 3 mm The bonding lug s provided on this unit are intended to connect a minimum of one No 8 AWG for US installation and two No 6 AWG for Canadian installations solid copper conductor between th...

Page 7: ...se containing metal weather conditions and geographical features The wireless control panel LCD screen can be sensitive to sunlight When exposed for extended peri ods the LCD screen will heat up and go black If this happens place the remote in a shaded area and allow the screen to cool down Do not attempt to adjust the contrast or the screen will be unreadable when it eventually cools When used ou...

Page 8: ...when seated in the cradle To turn the backlight on tap on the screen To use the Wireless Control Panel 1 Remove the Wireless Control Panel from the cradle Note With AC power connected to the cradle the Wireless Control Panel can be used while seated in the cradle 2 Tap the Wireless Control Panel touchscreen to turn the unit on The main screen is displayed The LCD backlight will turn off in two min...

Page 9: ...y icon bars scroll from left to right When the battery is fully charged the left to right scrolling of the battery icon will stop The battery icon will be solid when the battery is fully charged Note If the battery requires replacement only use Pentair replacement battery P N 522054 Sufficient charge left in the batteries to operate device Three solid bars indicate ample battery charge During batt...

Page 10: ...ontrol panel Note To avoid signal interference mount the Transceiver antenna a minimum of 10 ft away from the Load Center or Power Center any metal surface structure or air blower located in the immediate area of the equipment pad To mount the transceiver near the IntelliCenter Control System Load Center 1 Switch OFF the main power off to the IntelliCenter Control System Load Center 2 Remove the t...

Page 11: ...iver secure the wires with the terminal screws Make sure to match the color coding of the wires GND Black Green DT Yellow DT and Red 15 Connect the screw terminal connector onto the transceiver circuit board 9 Slide the case over the back plate Secure the case to the back plate using the two retaining screws 10 Proceed to Connecting the Transceiver to the IntelliCenter Control System Load Center o...

Page 12: ...r 2 Unlatch the front door latch and open the front door Remove the two retaining screws from the High Voltage Cover Panel and remove the panel 3 Loosen the two retaining screws securing from the top edge of the Outdoor Control Panel Fold down the Outdoor Control Panel to access the circuit board sockets connectors for the electrical connections Remove the panel from the enclosure see illustration...

Page 13: ... powered up the Wireless Control Panel will automatically synchronize with the system and will be ready for operation 8 Close the Load Center front door Fasten the spring latch 9 SWITCH ON AC POWER to the Load Center IntellliCenter Control System Wireless Control Panel Installation Guide COMMUNICATION PORTS A B 14 VDC 2 0A Max Combined IntelliCenter Control System COM PORT Strip 1 4 insulation fro...

Page 14: ...nter Control System Load Center Located outside at equipment pad Transceiver connects to the IntelliCenter Control System RS 485 COM Port on the main circuit board Wireless Control Panel RS 485 COM Port Transceiver Transceiver Connected to the IntelliCenter Control System Load Center ...

Page 15: ...creen on the Wireless Control Panel Tap Settings Advanced System Configuration Intellicenter Wireless Remote Setup to access the IntelliCenter Wireless Remote Setup Screen Pool Spa Features Lights Air Temp 65 F Schedule Usage Chemistry Status 3 3 84 78 92 85 8 00 A M 0 00 FW Version Device Name IntelliCenter Wireless Remote Setup Signal Strength 90dB 255 RSSI and LQI 12 Channel 3 Choose the best C...

Page 16: ...municate to the wireless transceiver located at the IntelliCenter Control System Load Center Tap a channel from 12 to 23 then tap Check to save and return to the previous screen The Channel number is displayed on the Channel button The RSSI and LQI are described as follows A high RSSI value means that packets are being received with a strong RF signal A high LQI value means that packets are being ...

Page 17: ... version Update from Ethernet Update from USB Update from Panel Firmware Update Tap this button to display the update option Displays the current IntelliCenter Control System firmware version Follow the screen prompts once firmware update has started Update from USB Tap this button to update the current firmware to a newer or earlier version from a USB memory device installed in the Outdoor Contro...

Page 18: ...d System Configuration Installation Setup Body Configuration Circuits Pumps Heaters Valves Chemistry Pool Spa Cover Remotes Setup iS4 QuickTouch II iS10 SpaCommand remotes Network and WIFI Setup Configure Ethernet Configure Wireless Network IntelliCenter Wireless Remote Setup Delays System System Information Detected Hardware System Diagnostic Information Firmware Update Update from Panel Update f...

Page 19: ...IntellliCenter Control System Wireless Control Panel Installation Guide 13 Notes ...

Page 20: ...less expressly noted names and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentair Water Pool and Spa Inc Those names and brands may be the trademarks or registered trademarks of those third parties Because we are continuously improving our products and services Pentair reserves th...