90°
13
1.
2.
A
B
13
At this point, the outside of the easyconnect cap must be rinsed.
!
CAUTION
This rinse procedure also removes chemical
residue from the internal parts of Cleanload Nexus, so it must always
be carried out correctly to eliminate the risk of contamination.
To activate rinse, rotate the Rinse Water Lever (Ref. 13) 90 degrees
clockwise (1) and raise it (2) to release rinse water.
NOTE
: when the Rinse Water Lever is in the raised ‘ON’ (position
2A), the Operating Handle cannot be moved.
A ON
B OFF
Note
: If the Operating Handle (Ref. 11) is NOT in the correct rinse
position (A), the Rinse Water Lever (Ref. 13) will rotate partially but
not engage or operate rinse.
!
CAUTION
The Rinse Water Lever should turn and engage
smoothly. If it does not, then check the Operating Handle is aligned
with the Lock Release Knob. Never attempt to force the Rinse
Water Lever.
1
2
3
4
Activate rinse for 10 seconds then rotate the container by 90
degrees to the left (clockwise) and then release the Rinse Water
Lever. Repeat 3 more times for a total of 40 seconds for optimum
rinsing.
!
CAUTION
Only rotate the container in a clockwise direction.
!
CAUTION
Never rotate the container anti-clockwise or the
easyconnect cap may become loose.
1 - 4 10 seconds at each position.
CLEANLOAD NEXUS
PNR-CN100-OIPM (10/12/21) ©2021 Pentair. All Rights.