6.4 Procedure for completely emptying a container
After following the instructions in sections 6.1 and 6.2 .
Turn the Operating handle (Ref. 11) all the way to the right (anti
clockwise).
This will quickly drain the container.
When the container is empty, the inside of the chemical container
can be rinsed.
90°
13
1.
2.
A
B
13
To activate rinse, rotate the Rinse Water Lever (Ref.13) 90 degrees
clockwise (step 1) and raise it to release rinse water (step 2).
NOTE
: When the Rinse Water Lever is in the raised ‘ON’ (position
2A), the Operating Handle cannot be moved.
A
ON
B OFF
11
A
NOTE
: The Operating Handle (Ref. 11) must be at the correct rinse
position (fully to the right at position A), If the handle is not aligned
correctly the Rinse Water Lever (Ref. 13) will rotate partially but it
will not be possible to raise it or operate rinse.
!
CAUTION
The Rinse Water Lever should turn and engage
smoothly. If it does not, then check the Operating Handle is fully to
the right. Never attempt to force the Rinse Water Lever.
CLEANLOAD NEXUS
PNR-CN100-OIPM (10/12/21) ©2021 Pentair. All Rights.
16