1
2
3
4
Activate rinse for 10 seconds then rotate the container by 90
degrees to the left (clockwise) and then release the Rinse Water
Lever. Repeat 3 more times for a total of 40 seconds for optimum
rinsing of the outside of the easyconnect cap and the inside of the
Cleanload Nexus.
!
CAUTION
Rotate the container only to the left (clockwise).
!
CAUTION
Never rotate the container anti-clockwise as the
easyconnect cap may become loose.
1-4
10 seconds at each position.
After cleaning the outside of the easyconnect cap and inside of
the Cleanload Nexus, release the Rinse Water Lever (Ref. 13).
Ensure that the Rinse Water Lever has returned to the horizontal
position shown.
The container can now be released by pulling the Lock Release
Knob (Ref. 12) and at the same time moving the Operating Handle
(Ref. 11) to the left.
Secure the partially empty container with the other hand to keep it
stable prior to lifting it off.
Put the dust cover back on the easyconnect cap for protection
during storage.
If this is the last container, ensure that the Cleanload Nexus
cleaning procedure detailed in section 7.1 is completed.
Replace the Top Cover (Ref 16) onto the Cleanload Nexus before
beginning spraying operations.
The remaining contents of the partially used container can be
used in the future with Cleanload Nexus, in the same way as a new
container.
CLEANLOAD NEXUS
PNR-CN100-OIPM (10/12/21) ©2021 Pentair. All Rights.
15