Pentair 93HPS114-M05 Installation And Operation Manual Download Page 1

pentair.com

INSTALLATION AND  

OPERATION MANUAL

L-1578 Rev. B (12-09-19)

HYDRAULICALLY DRIVEN STAINLESS STEEL

MULTISTAGE CENTRIFUGAL PUMPS 

WITH WETSEAL TECHNOLOGY

93HPS SERIES

KEEP FOR FUTURE REFERENCE

Pentair

375 5th A

ve

. NW

, Ne

w Bright

on

, M

N 55

112

Phone: (65

1) 766-6300 -OR

- 800-424-9776

Fax

: 800-32

3-6496

www

.pentair

.c

om

EC

REP

EU Authorized R

epr

esenta

tiv

e:

 

QN

ET B

V Hommer

ter

w

eg 286

 

6436 AM Ams

tenr

ade

, The Ne

therlands

 

KvK Zuid-Limbur

g 1409

15

11

Summary of Contents for 93HPS114-M05

Page 1: ...ENTRIFUGAL PUMPS WITH WETSEALTECHNOLOGY 93HPSSERIES KEEP FOR FUTURE REFERENCE Pentair 375 5th Ave NW New Brighton MN 55112 Phone 651 766 6300 OR 800 424 9776 Fax 800 323 6496 www pentair com EC REP EU Authorized Representative QNET BV Hommerterweg 286 6436 AM Amstenrade The Netherlands KvK Zuid Limburg 14091511 ...

Page 2: ...and Intermediate Storage 7 Assembly and Installation 8 Assembly 8 Installation 8 Control Systems 11 Commissioning Start Up Operation Shut Down 12 Information 12 Start up Operation Shutdown 12 Maintenance and Servicing 13 Information 13 Disposal 13 Cleaning 14 Maintenance Routine Servicing and Inspection 14 Troubleshooting 15 Replacement Parts 16 Declaration of Incorporation 18 Limited Warranty on ...

Page 3: ...чтения руководства Оригинальные копии этого руководства для насосы Hypro на английском языке Найти копию на ваш родной язык перейти к www hypropumps com Russian NO intente instalar su bomba antes de leer el manual Copias originales del manual para Hypro se provee de bombas en ingles Para encontrar una copia en tu idioma nativo ir a www hypropumps com Spanish NIE probować instalować pompy przed jej...

Page 4: ... to notify of installation operation or maintenance information that is important but not safety related This symbol is used to denote the presence of an electrical hazard that will result in personal injury death or property damage This symbol is used to denote the presence of a hazard that will result in personal injury death or property damage California Proposition 65 Warning This product and ...

Page 5: ...erial number Pump Technical Data 93HPS114 M05Y 001 All performance data is based on water as a carrier fluid Pump Specifications 93HPS114 M05 X 668 26 3 223 8 8 476 18 7 40 1 6 5 3 133 2X 11 4 126 5 0 3 8 97 168 6 6 Pump Hydraulic Motor Inlet Max PSI BAR Hydraulic Motor Outlet Max PSI BAR Max Flow RateGPM LPM Max Pressure PSI BAR 93HPS114 M05 3000 207 100 6 9 62 235 225 16 Max RPM Max Hyd Flow GPM...

Page 6: ... 120 140 0 2 4 6 8 10 12 14 16 0 50 100 150 200 HYD P bar Pump Outlet Pressure bar NPSHR m Pump Flow L min 93HPS114 M05Y NPSHR 0 200 400 600 800 1000 1200 1400 1600 1800 0 50 100 150 200 250 0 00 10 00 20 00 30 00 40 00 50 00 60 00 70 00 HYD P PSI Pump Pressure PSI NPSHR Ft Pump Flow GPM 93HPS114 M05Y NPSHR 93HPS114 M05Y 001 93HPS114 M05Y 001 ...

Page 7: ... by looking at the attached packing slips to establish what lifting equipment should be used Before installing the pump determine if all the components are present and undamaged If the pump is missing components contact customer service immediately Once the pump is unpacked dispose of the packaging in a manner compliant with local and national regulations Lifting Instructions Before attempting to ...

Page 8: ... void your warranty and could cause damage to property serious personal injury or death Electrical power cables and pump hoses must be routed where there is no risk of personnel tripping walking into or falling because they have been routed in areas where personnel are expected to move Electrical power cables and pump hoses should be routed according to local and national standards It is the insta...

Page 9: ...least the same size as their respective port and should have as few restrictions as possible Pump plumbing must be capable of withstanding the maximum suction and pressure generated by the pump Pump suction line must also be free of air leaks Use good quality suction hose that will not be collapsed by suction For best priming results the recommended orientation for the outlet port is horizontal wh...

Page 10: ... connected to low pressure return port on the tractor recommended for hydraulic motors the ports are identified on the motor casting Hydraulic supply lines should be at least the same size as the hydraulic motor port or larger Standard models come equipped with a check valve port adaptor on the motor outlet that should not be removed Standard ports are 8SAE pressure 10SAE tank Hooking up the motor...

Page 11: ...e port Once the orifice is installed test system performance and if system performance is low install the next largest orifice Continue this process until pump performance reaches the desired level or no orifices are installed in the adaptor 1 Ensure hydraulic system is off 2 Remove the pressure port adaptor from the motor using a 1 1 16 27mm wrench Make sure the o ring is on the metering orifice ...

Page 12: ...mponents where they can be a tripping hazard or become entangled in a moving component Ideally electrical cables hoses pipes and fittings should be routed overhead In the event electrical wiring must be routed over the ground operators are required to use rubber ramps if they cross a gangway Hypro centrifugal pumps should not be used if the ambient light is below 200lux Only use approved chemicals...

Page 13: ...nd drain all the fluid from the chamber 3 Replace the chamber fluid with new Hypro 93HPS wet seal Fluid 2160 0138 4 Pour 12 5 fl oz into the wet seal chamber The chamber should not be filled to the top 5 Re install the 1 8 NPTF plug in the port Maintenance and Servicing Information All maintenance should be done when machinery is stationary and has been isolated from its energy sources It is dange...

Page 14: ... of fluid being pumped and inlet feed conditions all affect the life and service interval of the pump Before attempting to service your pump be sure that it is disconnected from all energy sources Pump Maintenance and Servicing Pump Stack Replacement 1 Remove pump from service and secure to a stable work bench 2 Using a 1 1 4 hex head bit turn the discharge CLOCKWISE left hand threads to remove A ...

Page 15: ...ank Cut a notch or V in end of suction hose Clogged strainer Check strainer and clean regularly Low discharge Pump not primed Ensure inlet is fully flooded to prime If you are able to vent the outlet line to allow the inlet to flood Leak in suction line Check hose and fittings for leaks and correct Blocked suction line Inspect suction line and strainer and repair as necessary Impeller plugged Insp...

Page 16: ...ing can result in damage to property serious injury or death If the pump malfunctions or is defective it should be sent back to Pentair for service Model 93HPS114 Part Illustrations and Repair Kits Includes Models 93HPS114 M05Y AND M05 4 13 2 15 15 7 5 14 6 8 17 18 9 19 3 16 1 13 3 11 10 20 21 22 23 24 25 26 27 28 29 123 31 10 16 Form L 1578 Rev B 12 09 19 ...

Page 17: ...D 2 1 0255 2500C1 End Plate Sub Assy RR 8 8 2 1 0255 2500C4 End Plate Sub Assy RR Block 3 1 0542 2500 Motor M05 Shaft 4 1 0720 2602 Gerotor Housing Coated 5 1 0750 1584S Inlet Flange 6 1 0752 9310C4 Mounting Flange Speed Sensor Mount 6 1 0752 9310C3 Mounting Flange 7 1 1312 0030 Shaft Adapter 8 1 1410 0137 Tone Wheel 9 1 1410 0145 Spacer 10 1 1600 0086 Dowel Pin 11 1 1600 0097 Dowel Pin 12 1 1610 ...

Page 18: ... during installation by a third party Description PENTAIR Pump Type Roller Pumps Series Numbers 1502 1700 4001 4101 6500 7560 7700 Type Centrifugal Pumps Series Numbers 1442P 1539 1540 1542P 1543P 1550 90XX 9202 9203 9205 9206 9208 9262 9263 9253 9302 9303 9305 9306 9307 9308 9313 9314 9316 9342P 9343P 9742P 15HPS 93HPS Type Cleanload Assembly Series Numbers 3376 3378 Type Piston Plunger Pumps Ser...

Page 19: ...Notes 19 Form L 1578 Rev B 12 09 19 ...

Page 20: ...oducts returned which contain unknown fluids Pentair Hypro reserves the right to charge the returnee for any and all costs incurred for chemical testing and proper disposal of components containing unknown fluids Pentair Hypro requests this in order to protect the environment and personnel from the hazards of handling unknown fluids Be prepared to give Pentair Hypro full details of the problem inc...