Splice this ground wire to a copper conductor
that matches motor wire size specified in 
Table III. See Page 5 for wire splicing 
instructions.
Permanently ground pump, motor and control
box before connecting power cable to power
supply. Connect ground wire to approved
ground first and then connect to equipment
being installed.

Do not ground to a gas supply line.

Fire and electrical shock hazard. If

using a drop wire larger than No. 10 (5.5mm

2

)

(for example, No. 8 (8.4mm

2

) wire) between

pump and control box, run wire to a separate
junction box. Connect junction box to control
box with a No. 10 (5.5mm

2

) or smaller wire

(depending on amp rating of pump – see 
Table III).
For more information, contact your local code
officials.

WIRING CONNECTIONS:

All wiring must meet National Electrical Code or
Canadian Electrical Code and local code
requirements.
Use only copper wire when making connections
to pump and control box.
To avoid over-heating wire and excessive voltage
drop at motor, be sure that wire size is at least as
large as size listed in Table III for your horse-
power pump and length of wire run.

NOTICE: 

When built-in overheating protection

is not

provided, use with an approved overload

equipped motor control that matches motor
input in full load amps. Select or adjust overload
element(s) in accordance with control instruc-
tions. When built-in overheating protection 

is

provided, use with an approved motor control
that matches motor input in full load amperes.

TABLE I: 

Recommended Fusing Data - 60 Hz.,

Single Phase, 3 Wire Submersible Pump Motors

TABLE II: 

Recommended Fusing Data - 60 Hz.,

Single Phase 2 Wire Submersible Pump Motors

INSTALLATION WIRING DIAGRAMS -
SINGLE PHASE, 3 WIRE

For motors of 1

1

2

HP and above,

use magnetic starter to avoid damage to pressure
switch. Consult factory for wiring information.
See Page 4 for 2 Wire Hookup.

Hazardous voltage. Can shock,

burn, or kill.

Ground control box, all metal plumbing, and
motor frame with copper wire in compliance
with local codes. Use a ground wire at least as
large as the wires supplying power to motor.
Permanently close all unused openings in this
and other equipment.
Disconnect power to control box before working
on or around control box, pipes, cable, pump,
or motor.

3

Fuse Size  

HP

Volts

Stand

Dual Elem.

1/2

115

30

15

1/2

230

15

7

3/4

230

20

9

1

230

25

12

1.5

230

30

15

2

230

30

15

3

230

45

30

Fuse Size  

HP

Volts

Stand

Dual Elem.

1/2

115

30

15

1/2

230

15

7

3/4

230

20

9

1

230

25

12

14

12

10

8

6

4

3

2

1

0

Volts

HP

(2mm

2

)

(3mm

2

)

(5mm

2

)

(7mm

2

)

(13mm

2

)

(21mm

2

)

(25mm

2

)

(34mm

2

)

(41mm

2

)

(50mm

2

)

115

1/2

100

160

250

390

620

960

1190

1460

1780

2160

(30.5)

(48.8)

(76.2)

(118.9)

(189)

(292.6)

(382.7)

(445)

(542.5)

(638.4)

1/2

400

650

1020

1610

2510

3880

4810

5880

7170

8720

(121.9)

(198.1)

(310.9)

(490.7)

(765)

(1182.6)

(1466.1)

(1792.2)

(2185.4)

(2657.9)

3/4

300

480

760

1200

1870

2890

3580

4370

5330

6470

(91.4)

(146.3)

(231.6)

(365.8)

(570)

(880.9)

(1091.2)

(1332)

(1624.6)

(1972.1)

1

250

400

630

990

1540

2380

2960

3610

4410

5360

230

(76.2)

(121.9)

(192)

(301.8)

(469.4)

(725.4)

(902.2)

(1100.3)

(1344.2)

(1633.7)

1-1/2

190

310

480

770

1200

1870

2320

2850

3500

4280

(57.9)

(94.5)

(146.3)

(234.7)

(365.8)

(570)

(707.1)

(868.7)

(1066.8)

(1304.5)

2

150

250

380

620

970

1530

1910

2360

2930

3620

(45.7)

(76.2)

(118.9)

(189)

(295.6)

(466.3)

(582.2)

(719.3)

(893.1)

(1103.4)

3

120

190

300

470

750

1190

1490

1850

2320

2890

(36.6)

(57.9)

(91.4)

(143.3)

(228.6)

(362.7)

(454.2)

(563.9)

(707.1)

(880.9)

TABLE III: 

Power Supply Wire (Cable) Length in Feet (M)

1 Phase, 2 or 3 Wire Cable, 60 Hz (Copper Wire Size - Service to Motor)

Summary of Contents for PRO-SOURCE

Page 1: ...ran ais Pages 13 23 Instalaci n Operaci n Piezas Para mayor informaci n sobre el funcionamiento instalaci n o mantenimiento de la bomba Llame al 1 262 728 9181 Espa ol Paginas 24 36 2006 PENTAIR WATER...

Page 2: ...mp Make sure line voltage and frequency of power supply match motor nameplate voltage and frequency 3 Install pump according to all plumbing pump and well code requirements 4 Test well water for purit...

Page 3: ...mersible Pump Motors INSTALLATION WIRING DIAGRAMS SINGLE PHASE 3 WIRE For motors of 11 2 HP and above use magnetic starter to avoid damage to pressure switch Consult factory for wiring information See...

Page 4: ...ortant for control box selection TABLE IV Control Box Selection 4 HP Voltage Motor No Control Box No 1 2 115 214504 28010449 1 2 230 214305 28010549 214505 3 4 230 214307 28010749 214507 1 230 214308...

Page 5: ...the tightly wound tape is the only means of keeping water out of the splice the efficiency of the splice will depend on the care used in wrap ping the tape NOTICE For wire sizes larger than 8 7mm2 use...

Page 6: ...otch 33 electrical tape DO NOT damage pump wires NOTICE To avoid dropping the pump down the well or damaging cable or cable splices NEVER allow pump cable to support weight of pump PUMP INSTALLATION 1...

Page 7: ...mp and entire piping system including pressure tank from freezing Pre charged Pressure Tank Hookup See Figure 12 Page 8 for piping connections to pre charged pressure tank NOTICE Check air pre charge...

Page 8: ...NNECT PRE CHARGED TANK PRESSURE SWITCH PRESSURE GAUGE TO HOUSE SERVICE RELIEF VALVE UNION GATE VALVE FIGURE 12 Typical Submersible Installation with Pre charged Tank Installation Cut In PSI Cut Off PS...

Page 9: ...L DISCONNECT PRESSURE GAUGE AIR VOLUME CONTROL PRESSURE SWITCH TO HOUSE SERVICE GATE VALVE RELIEF VALVE 2 ft 6m SEE TABLE FIGURE 13 Standard Pressure Tank Installation CHECK VALVE DISTANCE TO TOP BLEE...

Page 10: ...ore reinstalling pump Fuses blow or overload protector trips when motor is running Low or high voltage Check that line voltage is within 10 of If voltage variation is more than 10 call rated nameplate...

Page 11: ...wire size and Install larger wire from control box to pump power supply wire size against Table III If necessary have power company raise supply Page 4 voltage Plugged intake screen Pull pump and che...

Page 12: ...leg ambient compensated extra quick trip overload relays of recommended size are not used our warranty is void Buyer s only remedy and PENTAIR s only duty is to repair or replace defective products a...

Page 13: ...courant d alimentation correspondent la fr quence et la tension indiqu es sur la plaque sig nal tique du moteur 3 Installer la pompe conform ment tous les codes relatifs la plomberie aux puits et aux...

Page 14: ...les 3 fils fonctionnant sur le courant monophas de 60 Hz TABLEAU II Fusibles recommand s Moteur des pompes submersibles 2 fils fonctionnant sur le courant monophas de 60 Hz SCH MAS DE BRANCHEMENT DU C...

Page 15: ...suppl mentaires ne sont pas importants dans le choix de la bo te de commande TABLEAU IV Choix des bo tes de commande N de N de bo tes ch Tension moteur de commande 1 2 115 214504 28010449 1 2 230 2143...

Page 16: ...es fils NOTA Dans le cas de fils de calibre n 8 7 mm2 ou plus gros les souder plut t que d u tiliser du mastic isolant lectrique Scotchfil se reporter la Figure 4 2 pissure prot g e par un tube thermo...

Page 17: ...ne tombe pas dans le puits et pour ne pas endommager le c ble ou les pissures du c ble NE JAMAIS laisser le c ble de la pompe supporter tout le poids de la pompe INSTALLATION DE LA POMPE 1 Si un r ser...

Page 18: ...e r servoir sous pression contre le gel Branchement sur un r servoir sous pres sion pr charg Se reporter la Figure 12 de la page 13 pour le branchement des tuyaux sur un r servoir sous pression pr cha...

Page 19: ...servoir pr charg D marrage en lb po 2 Arr t en lb po 2 Pression de pr charge 20 138 kPa 40 276 kPa 18 lb po 2 124 kPa 30 207 kPa 50 345 kPa 28 lb po 2 193 kPa 40 276 kPa 60 414 kPa 38 lb po 2 262 kPa...

Page 20: ...RGE SUP RIEUR CONTENANCE DES R SERVOIRS DISTANCE 42 gallons 159 L 2 pi 0 6 m 82 gallons 310 L 3 pi 0 9 m 120 gallons 454 L 5 pi 1 4 m 220 gallons 833 L 5 pi 1 4 m 315 gallons 1 192 L 10 pi 3 0 m 525 g...

Page 21: ...er la pompe Les fusibles fondent ou le dispositif de protection contre les surcharges se d clenche lorsque le moteur fonctionne Haute ou basse tension S assurer que la tension du courant Si la fluctua...

Page 22: ...le calibre des fils d arriv e et le calibre du grand diam tre entre la bo te de commande et la pompe c ble descendant dans le puits en se Au besoin demander la compagnie d lectricit d aug reportant au...

Page 23: ...thermiques d clenchement extra rapide trois pieds et temp rature ambiante compens e de la dimension recommand e ne sont pas utilis s notre garantie sera annul e Le seul recours de l acheteur et la se...

Page 24: ...24...

Page 25: ...la tensi n y la frecuencia que aparecen en la placa de f brica del motor 3 Instale la bomba conforme a todos los requisitos de fontaner a y de los c digos para bombas y pozos 4 Haga una prueba con el...

Page 26: ...t n dar de 60 Hz monof sicos y trifilares y motores de bombas sumergibles de marcha por compen sador trifilares TABLA II Informaci n sobre fusibles recomen dados motores de bombas sumergibles de 60 Hz...

Page 27: ...trol TABLA V Selecci n de la caja de control hp Voltaje Motor No Caja de control No 1 2 115 214504 28010449 1 2 230 214305 28010549 214505 3 4 230 214307 28010749 214507 1 230 214308 28010849 214508 1...

Page 28: ...l empalme depender del cuidado que se tenga cuando se envuelva la cinta AVISO Para hilos de tama o m s grande que 8 7 mm2 use uniones soldadas en lugar de masilla Scotchfil ver Figura 4 2 Empalme term...

Page 29: ...otch 33 NO da e los hilos de la bomba AVISO Para evitar dejar caer la bomba en el pozo o da ar el cable o los empalmes del cable NUNCA deje que el cable de la bomba soporte el peso de la bomba INSTALA...

Page 30: ...la garant a Proteja la bomba y todo el sistema de tuber as incluyendo el tanque de presi n para que no se congelen Conexi n del tanque de presi n precargado Ver la Figura 12 p gina 31 para las conexi...

Page 31: ...que precargado PSI de activaci n PSI de desactivaci n Presi n de precarga 20 138 kPa 40 276 kPa 18 PSI 124 kPa 30 207 kPa 50 345 kPa 28 PSI 193 kPa 40 276 kPa 60 414 kPa 38 PSI 262 kPa CASQUETE VENTIL...

Page 32: ...IFICIO SUPERIOR DE PURGA TAMA O DEL TANQUE DISTANCIA 42 gal n 159 L 2 0 6 m 82 gal n 310 L 3 0 9 m 120 gal n 454 L 5 1 4 m 220 gal n 833 L 5 1 4 m 315 gal n 1 192 L 10 3 0 m 525 gal n 1 987 L 15 4 6 m...

Page 33: ...cal antes de volver a instalar la bomba Los fusibles est n quemados o el protector contra sobrecarga se dispara cuando el motor est en marcha Tensi n baja o alta Verifique que la tensi n de l nea se...

Page 34: ...o m s grande de la caja de control a hilo de entrada y el tama o del hilo de la bomba Si es necesario haga que la empresa de energ a suministro de corriente contra la Tabla III eleve la tensi n de sum...

Page 35: ...mpensaci n ambiental y disparo extra r pido del tama o recomendado nuestra garant a quedar anulada El nico recurso del comprador y la nica obligaci n de PENTAIR ser n el de reparar o reem plazar los p...

Reviews: