LEGEND® II INSTALLATION MANUAL
F. Hooking up the Legend
®
II
1. Remove the Pressure Tester from the free end of
the Feed Hose by unscrewing the Mender Nut,
left hand thread (reverse). (See illustration below.)
3. Carefully twist lock the Sand & Silt debris bag
onto the top of the Legend
®
II Vacuum Tube. Make
sure there is a Rubber Debris Valve attached to
the top of the Vacuum Tube before locking on the
Sand & Silt bag, (this valve is similar to a check
valve to help keep debris inside the bag when
the water pressure is off).
4. Attach the Sand & Silt bag clip to the space
between the Back-Up Valve and the 18” hose.
5. Gently place the Legend
®
II in the pool. Turn on
the pool filtration pump.
6. Check to make sure the wheel RPM is between
25-32. See
page 5
for instructions on wheel RPM.
G. Checking Operation
When operating correctly, the Legend
®
II will travel
in a random pattern throughout the pool, vacuuming
and sweeping the bottom. The climbing ability of the
Legend
®
II is dependent on the pools structure and
water flow coming into the pool. It will perform more
efficiently in pools without sharp angles or curves in
the transition from the floor of the pool to the wall.
The Legend
®
II comes with a Twist Lock Pressure
Relief Valve (Wall Fitting). If the Legend
®
II is receiving
too much water pressure, the Pressure Relief Valve
in the Wall Fitting will release the excess water
pressure.
Approximately every three minutes and 30 seconds
the Legend
®
II will go into a back-up mode. The
Back-Up Valve cycle time, while in the back-up mode,
is approximately 30 seconds, pulling the Legend
®
II
from it’s current location increasing it’s random
pattern.
The Sweep Hose operates in a gentle sweeping
motion to prevent debris from becoming trapped in
hard to reach corners of the pools.
If the Legend
®
II does not travel to all areas of the
pool, turn off the pool filtration pump and make the
necessary adjustments from the instructions on the
next page.
4
FEED
HOSE
MENDER
NUT
THRUST
JET
HEAD FLOAT
FEED MAST
SWIVEL
RUBBER
DEBRIS
VALVE
FEED HOSE
MENDER NUT
O-RING
2. Place mender nut on Legend
®
II Swivel Mast.
Connect the open end of the Feed Hose to the
top of the Legend
®
II Swivel Mast and secure with
the mender nut. The arch of the Feed Hose should
align in the same direction as the Swivel Mast,
there should be no twist in the Feed Hose after
connection. (See illustration below.)
Summary of Contents for Legend II
Page 23: ...Notes ...