17
Section 4
Installation and Removal
The following information describes how to install the IntelliFlo
®
VS pump.
Note: Before installing this product, read and follow all warning notices and instructions.
IntelliFlo VS Kit Contents
• IntelliFlo
®
VS 3050 pump
Installing the IntelliFlo
®
VS
Only a qualified service person should install the IntelliFlo VS pump.
Location
1. Install the pump as close to the pool or spa as possible. To reduce friction loss and improve
efficiency, use short and direct suction and piping returns.
2. Install a minimum of 5 feet (1.5 m) from the inside wall of the pool and spa.
3. Install the pump a minimum of 2 feet (0.6 m) from the heater outlet.
4. Do not install the pump more than 8 feet (2.4 m) above the water level.
5. Install the pump in a sheltered well ventilated location protected from excessive moisture, (i.e., rain,
sprinklers, etc.).
6. For hot tubs and spas, do not install within an outer enclosure or beneath the skirt of a hot tub or spa.
7. Install the pump with a rear clearance of at least 6 inches (15 cm) so that the motor can be removed
easily for maintenance and repair.
Piping
For improved pool plumbing, it is recommended to use a larger pipe size. When installing the inlet
and outlet fittings (male adaptors), use thread sealant.
Do not install 90° elbows directly into pump inlet or outlet. A valve, elbow or tee installed in the
suction line should be no closer to the front of the pump than five (5) times the suction line pipe
diameter. This will help the pump prime faster and last longer.
Flooded suction systems should have gate valves installed on suction and discharge pipes for
maintenance, however, the suction gate valve should be no closer than five (5) times the suction pipe
diameter as described above.
Check Valve
Check valves must be used when the IntelliFlo
®
VS is used in parallel with other pumps. IntelliFlo
®
pumps cannot be used in series with other pumps.
English
Summary of Contents for INTELLIFLO VS-3050
Page 157: ......
Page 158: ...357219...