STANDARD LIMITED WARRANTY

 

 

 

 

 

HYDROMATIC

®

 warrants its products against defects in material and workmanship for a period of 12 months 

from the date of shipment from Hydromatic or 18 months from the manufacturing date, whichever occurs first - 
provided  that  such  products  are  used  compliance  with  the  requirements  of  the  Hydromatic  catalog  and          
technical  manuals  for  use  in  pumping  raw  sewage,  municipal  wastewater  or  similar,  abrasive  free                 
non-corrosive liquids. 

During the warranty period and subject to the conditions set forth, Hydromatic, at its discretion, will repair or 
replace  to  the  original  user,  the  parts  which  prove  defective  in  materials  and  workmanship.  Hydromatic 
reserves the right to change or improve its products or any portions thereof without being obligated to provide 
such a change or improvement for prior sold and/or shipped units.

Start-up reports and electrical schematics

 may be required to support warranty claims. Warranty is 

effective only if Hydromatic authorized control panels are used. All seal fail and heat sensing devices must be 
hooked up, functional and monitored or this warranty will be void. Hydromatic will only cover the lower seal 
and labor thereof for all dual seal pumps. Under no circumstance will Hydromatic be responsible for the cost 
of field labor, travel expenses, rented equipment, removal/reinstallation costs or freight expenses to and from 
the factory or an authorized Hydromatic service facility.

This limited warranty will not apply:

 (a) to defects or malfunctions resulting from failure to properly 

install, operate or maintain the unit in accordance with the printed instructions provided; (b) to failures resulting 
from abuse, accident or negligence; (c) to normal maintenance services and parts used in connection with such 
service; (d) to units which are not installed in accordance with applicable local codes, ordinances and good 
trade practices; (e) if the unit is moved from its original installation location; (f) if unit is used for purposes other 
than for what it is designed and manufactured; (g) to any unit which has been repaired or altered by anyone 
other than Hydromatic or an authorized Hydromatic service provider; (h) to any unit which has been repaired 
using non factory specified/OEM parts.

Warranty Exclusions:

 HYDROMATIC MAKES NO EXPRESS OR IMPLIED WARRANTIES WHICH EXTEND 

BEYOND THE DESCRIPTION ON THE FACE HEREOF. HYDROMATIC SPECIFICALLY DISCLAIMS THE IMPLIED 
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR ANY PARTICULAR PURPOSE.

Liability Limitation:

  IN  NO  EVENT  SHALL  HYDROMATIC  BE  LIABLE  OR  RESPONSIBLE  FOR                    

CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES RESULTING FROM OR RELATED IN ANY MANNER 
TO ANY HYDROMATIC PRODUCT OR PARTS THEREOF. PERSONAL INJURY AND/OR PROPERTY DAMAGE 
MAY  RESULT  FROM  IMPROPER  INSTALLATION.  HYDROMATIC  DISCLAIMS  ALL  LIABILITY,  INCLUDING   
LIABILITY  UNDER  THIS  WARRANTY,  FOR  IMPROPER  INSTALLATION.  HYDROMATIC  RECOMMENDS   
INSTALLATION BY PROFESSIONALS.

Some  states  do  not  permit  some  or  all  of  the  above  warranty  limitations  or  the  exclusion  or  limitation  of              
incidental  or  consequential  damages  and  therefore  such  limitations  may  not  apply  to  you.  No  warranties          
or  representations  at  any  time  made  by  any  representatives  of  Hydromatic  shall  vary  or  expand  the                 
provision hereof.

USA

740 East 9th Street, Ashland, Ohio 44805

Tel: 419-289-3042  Fax: 419-281-4087

CANADA

269 Trillium Drive, Kitchener, Ontario, Canada N2G 4W5

Tel: 519-896-2163  Fax: 519-896-6337

Warranty Rev 02/09

Summary of Contents for HYDROMATIC H4QX

Page 1: ...oups C D FM 02 11 Item E 03 505 Part 5625 505 1 2011 Pentair Pump Group Inc NOTE To the installer Please make sure you provide this manual to the owner of the equipment or to the responsible party who maintains the system Installation and Service Manual For use with product built with USEM motor Hazardous Location Motor End ...

Page 2: ...ailure Probes All our hazardous location submersible pumps have two factory installed moisture detectors seal failure probes They are in a normally open series circuit in the seal chamber Under normal operating conditions the circuit remains open If the lower seal leaks and moisture enters this chamber the moisture would settle to the bottom of the chamber and will complete the circuit between the...

Page 3: ... line to prevent freezing This can be done only with short discharge lines otherwise water will return to the sump and cause short cycling of the pump Making Electrical Connections All electrical wiring must be in accordance with local code and only qualified electricians should make the installations Complete wiring diagrams are included for use in making the installation All wires should be chec...

Page 4: ...SEAL PROBES 300 VAC 20 MA POWER CORD CONTROL CORD SEE TYPICAL CONTROL CIRCUITRY BELOW M RUN LIGHT SEAL FAILURE INDICATOR D C TO SEAL PROBES IN PUMP MOTOR SEAL FAILURE RELAY LEVEL CONTROL CIRCUITRY H O A H A R OVERLOADS CAPACITORS AND OR CONTROLS SHOULD BE LOCATED OUTSIDE HAZARDOUS AREA AND ENCLOSED IN AN APPROPRIATE ENCLOSURE NOTE TYPICAL CONTROL CIRCUITRY Typical FM Only Schematics ...

Page 5: ...Wiring Diagrams PROBE TEST RESISTOR ON HAZARDOUS LOCATION ONLY PROBE TEST RESISTOR ON HAZARDOUS LOCATION ONLY PROBE TEST RESISTOR ON HAZARDOUS LOCATION ONLY 5 ...

Page 6: ... pump cords from the rest of the system Pump cords may be disconnected at control panel on sump mounted control panels and cord assembly taken with pump CAUTiON if cord openings from sump to control panel are open gases from sump could enter panel and an explosive condition could exist Pump cords may be disconnected at pump by removing the cord and cap assembly unplugging sensor wires and removing...

Page 7: ...complete unit under water and check for leaks If seals were okay refill seal chamber with oil Lay pump on side for this oil filling with oil fill hole upright Do not completely fill leave oil about 1 below plug hole Use only Hydromatic submersible oil or high grade transformer oil in this chamber Replace plug use Permatex on threads 13 Refill motor chamber with oil through connection box opening U...

Page 8: ...____________________________________________ ______________________________________________ ______________________________________________ 8 10 Examine all O rings for nicks before reusing 11 Use Locktite red on socket head locking screw in end of shaft 12 Before refilling chamber with oil air test as described in replacing stator 13 Refill both chambers with oil as described in replacing stator 1...

Page 9: ...Motor End Parts 9 ...

Page 10: ... B7 Insulator Split Bolt B8 Oil 24709110000 24709110000 24709110000 24709110000 24709110000 24709110000 B11 Cord Cap 35 11400 083 5 11400 083 5 11400 083 5 11400 083 5 11400 084 5 11400 084 5 Connector stator to conn box B4 7 5 10 HP 7 5 10 HP 15 HP 15 HP 15 HP 15 HP 6 Pole 1150 RPM 460 3 1150 575 3 1150 200 3 1150 230 3 1150 460 3 1150 575 3 1150 Item Description B1 Connection Box 11408 001 5 114...

Page 11: ...rd Cap 35 11400 083 5 11400 087 5 11400 087 5 11400 087 5 11400 083 5 11400 087 5 11400 087 5 B4 Connector stator to conn box B5 Connector box to cord cap B7 Insulator Split Bolt 25 HP 25 HP 30 HP 30 HP 30 HP 30 HP 40 HP 4 Pole 1750 RPM 460 3 1750 575 3 1750 200 3 1750 230 3 1750 460 3 1750 575 3 1750 200 3 1750 Item Description B1 Connection Box 11408 001 5 11408 000 5 11408 004 5 11408 005 5 114...

Page 12: ...12 D7 1 D1 D2 D5 D3 D4 D4 D3 D5 D2 1 D7 D1 D4 D5 D2 1 D7 D1 1 D7 D1 D4 D5 D2 S6AX S4KX S6LX S4LX Wet End Parts ...

Page 13: ...13 D2 D5 1 D7 D1 D1 D7 1 D2 D5 D4 D4 D2 D5 D3 1 D7 D1 D4 D5 D2 1 D1 D7 H4QX S4LVX S8FX S4BX Wet End Parts ...

Page 14: ... 2594 021 2 2594 021 2 10 25 2594 007 2 10 31 11043 011 2 10 38 2594 016 2 2594 016 2 2594 016 2 10 5 2594 008 2 13694 007 2 2594 008 2 2594 008 2 13720 007 2 15151 003 2 10 85 2594 009 2 11 13692 005 2 2594 010 2 13694 005 2 2594 010 2 13720 005 2 11 25 11043 008 2 2594 011 2 11 38 2594 020 2 2594 020 2 2594 020 2 11 5 11043 001 2 2594 012 2 2594 012 2 15151 001 2 11 63 2594 018 2 11 88 2594 000 ...

Page 15: ...__________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ _____________...

Page 16: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...

Page 17: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...

Page 18: ...rdance with the printed instructions provided b to failures resulting from abuse accident or negligence c to normal maintenance services and parts used in connection with such service d to units which are not installed in accordance with applicable local codes ordinances and good trade practices e if the unit is moved from its original installation location f if unit is used for purposes other tha...

Page 19: ......

Page 20: ...g Line Voltage _________________________________Actual ___________________________________ Voltage to Pumps _____________________________________Actual ___________________________________ Type of Junction Box __________________________________Manufacturer of Junction Box ______________ Are Floats Installed in Wet Well Yes No Are Floats Set to Engineer s Specs Yes No Are Floats Wired for Proper Seq...

Reviews: