background image

Part #110731-001

Product Manual:

Model #1475D & #1485D (12VDC)

Axial "AIRPAC" Ventilator

T.A. Pelsue Company

2500 South Tejon Street

Englewood, Colorado, USA  80110

Tel. 800-525-8460 or 303-936-7432 

Fax. 303-934-5581

Internet: www.pelsue.com  

Email: [email protected]

ISO 9001 Certified

Summary of Contents for AIRPAC 1375D

Page 1: ...odel 1475D 1485D 12VDC Axial AIRPAC Ventilator T A Pelsue Company 2500 South Tejon Street Englewood Colorado USA 80110 Tel 800 525 8460 or 303 936 7432 Fax 303 934 5581 Internet www pelsue com Email sales pelsue com ISO 9001 Certified ...

Page 2: ... 110731 001 Product Manual Model 1475D 1485D Axial AIRPAC Ventilator Revision 05 Date 03 04 2014 Page 2 ...

Page 3: ...d a continuing reputation for excellence in the production of fine products for a broad spectrum of industry throughout the world Now in our second generation of family direction continued commitment to innovation and quality makes Pelsue a leading source of equipment for many types of confined spaces We specialize in safety retrieval fall arrest ventilation cable placing splicing and maintenance ...

Page 4: ...y 2 0 Introduction Product Information 7 2 1 Serial Number 3 0 Configuration Assembly 8 3 1 Parts Diagram List 1475D 1485D 3 2 Parts Diagram List Ventilator Assembly 3 3 Parts Diagram List Hose Canister Assembly 3 4 Parts Diagram List Adapter Sub Assembly 4 0 Safety 13 4 1 Safety Alert Symbol 4 2 General Safety Information 5 0 Product Operation 15 5 1 Product Description Capabilities 5 2 Start Up ...

Page 5: ...omer satisfaction is one of the differentiators that sets you apart from the pack and yields a competitive advantage Therefore we will support total customer satisfaction by implementing the ISO 9001 Quality System and providing the necessary atmosphere and training to nurture this concept throughout our organization We will make every business decisionas though the quality of the part or service ...

Page 6: ...ereunder shall be limited to the repair or replacement of the product or component as set forth above and shall not include any liability whatsoever for damages caused by such failure including but not limited to consequential or incidental dam ages flowing from use or lack of use of product Any replacement repair modification installation or other service performed by the T A Pelsue Company shall...

Page 7: ...ers the Pelsue Model 1475D 1485D Axial AIRPAC Ventilator Use the Table of Contents as a guide to find specific information Keep this manual handy for frequent reference and to pass on to new operators 2 1 Serial Number Product Serial Number Always give your dealer the serial number of your Pelsue confined space ventilator product when ordering parts or requesting service or other infor mation The ...

Page 8: ...bly Refer to parts list if replacement parts are required Replacement parts can be ordered from the T A Pelsue Com pany at 800 525 8460 3 1 Parts Diagram List Table 3 1b 1485D Parts List Table 3 1a 1475D Parts List ITEM NUMBER PART NUMBER DESCRIPTION QUANTITY 3 109997 003 VENTILATOR ASSEMBLY MODEL 1325D FOR USAGE WITH AIR PAC MODELS 1 4 102095 999 CANISTER SUB ASSEMBLY AIR PAC FIxED MOUNT TO VENTI...

Page 9: ... 110731 001 Product Manual Model 1475D 1485D Axial AIRPAC Ventilator Revision 05 Date 03 04 2014 Page 9 3 1 Parts Diagram List continued Figure 3 1a 1475D 1485D Parts Diagram 4 6 5 3 7 ...

Page 10: ...ON 1400 SERIES BLOWERS CARBON STEEL 1 13 100405 004 STRAIN RELIEF WATERTIGHT 1 2 HUB 0 250 0 375 DIAM 1 14 100188 001 FOOT RUBBER 3 4 OD W WASHER 4 15 100050 006 WASHER FLAT 10 TYPE A W PLATED 4 16 110733 001 LOCkNUT HEx WITH NYLON INSERT 10 32 BLACk 4 17 104638 001 SCREW SET CUP POINT 8 32 x 3 8 GRADE 5 PLATED 1 18 118518 001 RIVET STAVEx BLIND FLANGE DOME BLACk 0 188 DIA 18 19 118519 001 RIVET S...

Page 11: ...5 8460 11 5 3 4 7 8 6 10 12 9 9 IteM NuMBeR PARt NuMBeR DeSCRIPtION QuANtIty 3 100768 002 WELDMENT HOSE CANISTER 1300D 1400D AIR PACS 1 4 118972 001 RETAINER HOSE CARRIER NYLON WEBBING TYPE 1 5 106942 001 HANDLE PULL TYPE BLk PLASTIC FOR 1590 1690 SERIES 1 6 100188 002 FOOT RUBBER 1 1 2 OD W REC WASHER 1 7 100050 009 WASHER FLAT 1 4 IN TYPE A W PLATED 1 8 100048 114 LOCk NUT HEx 1 4 20 NYLON INSER...

Page 12: ...LACk 188 DIA 3 8 101043 002 SCREW MACHINE HEx HD 10 24 UNC x 1 2 PLATED 1 3 4 Parts Diagram List Refer to the following parts breakdown diagram Figure 3 4a and the accompanying parts list Table 3 4a for iden tification of parts of Adapter Sub Assembly in the event replacements become necessary The parts list table displays applicable part numbers descriptions and quantity per assembly Refer to par...

Page 13: ...and capabilities of the 1475D 1485DAxial AIRPAC Ventilator and alert you to all good safety and operating practices while using the system Remember you are the key to safety Good safety practices not only protect you but also the people around you Make these practices a working part of your safety program Be certain that everyone operating in or around a confined space is familiar with the procedu...

Page 14: ...ited to but must include the following items Do not use the Ventilator for anything other than its intended use 1 Do not wear loose clothing that can become entangled in operating machinery Do not operate the Ventilator without 2 inlet or outlet screen guards in place Do not place fingers or any other object through inlet or outlet screens 3 Always operate the Ventilator from a properly grounded r...

Page 15: ...ower source can be used with a minimum in rush rating amperage of 50 amps and a continuous duty of 15 to 18 amps Many automotive power ports cigarette lighter outlets are not rated for the required 15 amp draw the T A Pelsue Company is not liable to any damage incurred when connecting the blower to an under rated 12VDC power supply source Axial AIRPAC Ventilator 1475D 1485D General Specifications ...

Page 16: ...ould be used as a guide to determine whether the equipment is in good operating condition prior to usage Equipment that is not in good condition can endanger the safety of the entrant and attendant during use The Pre Operation Visual Inspection is not limited to but must include the following items a Check the Ventilator inlet and outlet guard screens for obstructions b Remove any objects around t...

Page 17: ... the confined space Refer to Fig 5 2b Connect the ventilator to a suitable 12VDC power source as described in section 5 1 b Extend and place the ventilator hose as required c When ventilator operation is no longer required unplug the power cord Coil and store the power cord in the open d ing of the molded handle or wrap the cord around the molded legs Important Notes During confined space entry op...

Page 18: ... 110731 001 Product Manual Model 1475D 1485D Axial AIRPAC Ventilator Revision 05 Date 03 04 2014 Page 18 Notes ...

Page 19: ... 110731 001 Product Manual Model 1475D 1485D Axial AIRPAC Ventilator Revision 05 Date 03 04 2014 Page 19 Notes ...

Page 20: ...ISO 9001 Certified T A Pelsue Company 2500 South Tejon Street Englewood Colorado USA 80110 Toll free 800 525 8460 or 303 936 7432 Fax 303 934 5581 Internet www pelsue com Email sales pelsue com ...

Reviews: