PEI Enviro-Septic/SimpleSeptic Template 1A 2003 Instruction Manual Download Page 1

How To Use This Template, 

Continued 

 

Procedure 2   

Follow these steps to use the template to draw a    

 

end view

        sloping system end view.

 

 

Step Action 

 

Use the % slope tool               as a protractor to create a 

 

desired percentage of slope. 

 

Example

 

 

 

 

Base Line 

 

Use the pipe end view cutouts                   to draw end 
views of lines of pipe on the slope. 

 

Example:

 

 

 

 

 

 

Base Line 

 

Use the % slope tool                   to add the same  

 

percentage of slope line as used in step 1 over the top of 
the sloped pipes. 

 

Example: 

 

 

 

 

      Base Line 

 

Add a slope ratio line                  to each side of the 
system. 

 

Example: 

 
 
 

 

 

   Base Line 

 
 

Curved           

The bend tools                                     indicate the 

 

 

configuration

  

maximum pipe bends in 1”-10’ and 1”-20’ curved 
configurations. 

 
 
 
 
 
   Maximum 

bend 

at 

1”-20’ 

 

 
 

 

Enviro-Septic

®

 U.S. Patent Nos. 6,461,078; 5,954,451; 6,290,429 with other patents pending.  

Canadian Patent Nos. 2185087; 2187126 with other patents pending.  Simple-Septic

®

 U.S. 

Patent No. 5,606,786.  Presby Maze

®

 U.S. Patent No. 5,429,752. 

Enviro-Septic

®

, Simple-Septic

®

, and Presby Maze

®

 are registered trademarks of Presby 

Environmental Inc.  Multi-Level

TM

 , is a trademark of Presby Environmental, Inc. 

© 2003 Presby Environmental, Inc.  All rights reserved.  Publication date:  July 2003 

 

13b 

13b 

10 

13a 

12 

Instruction Manual for use with 

the Enviro-Septic

®

/Simple-

Septic

® 

Template 1A 2003 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

         Template 1A 2003

 

 

Purpose

 

This Enviro-Septic

®

/Simple-Septic

® 

Template 1A 

2003 is a drawing aid for our septic system designs.  
This tool is used to accurately draw pipe and system 
layouts in top and end views, and also to draw 
sloping and curved configurations. 

 

Prerequisite

   

System length and pipe spacing are required to use 

this template.  Use our “Enviro-Septic

®

 & Simple-

Septic

® 

Leaching Systems Design and Installation 

Manual” and your State Attachment to calculate these 
figures and other essential data. 

 
 
 
 
 
 
 
 

PRESBY ENVIRONMENTAL, INC. 2003

/SIMPLE-SEPTIC

®

TEMPLATE 1A 2003

PRESBY ENVIRONMENTAL, INC

  BOX 617
  SUGAR HILL, NH 03585
  TEL: 1-800-473-5298

4'DIA.

SM. TANK

2.75'

2.5'

2.25'

2.5'

2.75'

3.5'

10

1" = 10'

20

30

2.75'

4'

3.5'

3'

1.75'

1.75'

1.5'

2.5'

5

2.25'

2'

2'

1" = 

5'

1.5'

10

15

3.5'

ENVIRO-SEPTIC

4.5'

5'

©

3' DIA.

1.75'

2'

1.5'

2.25'

20

1" = 20'

40

60

2:1

MAX. BEND  1" = 10'

40

5'

5'

5:1

4:1

3:1

55

®

% O

F S

LOP

E

SLO

PE 

RAT

IO

5' DIA.

35

15

5

25

45

1" = 20'

MAX. BEND 

10'

LG. TANK

80

D-BOX LG

D-BOX SM

PRESBY ENVIRONMENTAL, INC.

INNOVATIVE SEPTIC TECHNOLOGIES

Route 117 • PO Box 617 • Sugar Hill, NH 03585

Tel: 1-800-473-5298 • Fax: (603) 823-8114

www.PresbyEnvironmental.com